FreshJet
See fig. b
230 Vwcable
➤ Connect the roof air conditioner with the 230 Vwvoltage supply.
Connect the cables (1) to a cable connector (2).
Remote light switch (not included in the scope of delivery)
You can connect the lighting to a remote light switch. This enables you to switch on
the lighting remotely.
To do this, proceed as follows:
➤ Disconnect the 2-pin plug (6) from the socket on the circuit board of the air outlet
unit.
➤ Connect the two cables of the remote light switch to the 2-pin plug (5).
➤ Insert the 2-pin plug (5) into socket on the circuit board (6).
12 Vg cable
You can connect the lighting to the battery. This enables you to switch on the lighting
even if the 230 Vw voltage supply is not connected.
To do this, proceed as follows:
➤ Connect the positive cable and the negative cable with the battery.
Connecting the circuit board
➤ Insert the 12-pin plug (3) in the socket (7) on the circuit board of the air outlet unit.
➤ Connect the 2-pin connector plug (2) to the wire from CI-Bus master panel
(optional).
See fig. c
➤ Choose the suitable seal in accordance with the following table:
Roof thickness
25 – 30 mm
30 – 40 mm
40 – 60 mm
➤ Position the seal with the adhesive side on the ADB.
EN
Seal type
15 mm
30 mm
45 mm
Installation
17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Freshjet fj 2000Freshjet fj 2200Freshjet fj 3200

Table des Matières