Dometic FRESHJET FJ 1700 Instructions De Montage page 14

Masquer les pouces Voir aussi pour FRESHJET FJ 1700:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
Installation
Electrical connection
The complete circuit diagram can be found in fig. i:
Item
Description
1
230 Vw mains
2
Compressor
3
Fan condenser
4
Fan condenser (FreshJet3200 only)
5
Fan evaporator
6
Battery
7
Remote socket
8
Temperature sensor
9
Heating (FreshJet1700,2000, 2200 only)
10
Heat Pump (FreshJet3200 only)
11
Soft Start (FreshJet2000, 2200,3200 only)
Keys for fig. j:
Item
Description
1
Remote light switch
2
Circuit board in the air outlet unit
See fig. d
230 Vw cable
➤ Connect the roof air conditioner with the 230 Vw voltage supply.
Connect the cables (1) to a cable connector (2).
Remote light switch (not included in the scope of delivery)
You can connect the lighting to a remote light switch. This enables you to switch on
the lighting remotely.
To do this, proceed as follows:
➤ Disconnect the 2-pin plug (3) from the socket on the circuit board of the air outlet
unit.
14
FreshJet
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Freshjet fj 2000Freshjet fj 2200Freshjet fj 3200

Table des Matières