GB
Congratulations on your purchase and thank you for choosing our unit.
Visit our Internet site www.flaemnuova.it to view the whole range of Flaem products
Carefully read these instructions and keep them in a safe place for future reference.

IMPORTANT SAFEGUARDS

This a medical device for home use. It is to be used only upon medical prescription.
Before using the unit for the first time, and periodically throughout its life, check the power supply cord for any damage.
If there is any damage, unplug immediately and return the product to an authorized dealer for service.
• Children and disabled persons should always use the unit under strict supervision of an adult who has read this
manual.
• The unit should not be used in the presence of anaesthetic substances inflammable with air, oxygen or nitrous oxide.
• Never use adopters for power supplies different from the one indicated on the bottom of the unit. Keep the cord away
from heated surfaces.
Do not handle the plug with wet hands. Never use the unit while having a bath or shower. Never submerge the
unit in water; should this accidentally occur, unplug immediately - do not reach for the submerged the unit, always
unplug first. After removing a unit from water, do not use again, ensure it is returned to an authorized service dealer.
• Do not wash the unit under running water or do not submerge it in water.
• Unit with case not protected against ingress of liquids.
• Always unplug the unit immediately after use.
• Repairs should be performed by authorized personnel only. Unauthorized repairs will invalidate the warranty and may
represent a hazard to the user.
INSTRUCTIONS FOR USE
Before each use, the nebulizer and the accessories should be cleaned according to the instructions in the section
"CLEANING AND DISINFECTION ".
1. Plug the power cord into a power socket corresponding to the voltage of the unit.
2. Carefully wash your hands before preparing the inhalation therapy.
3. Open the medication nebulizer by turning the upper part (9c) counterclockwise.
4. Pour the drug prescribed by the physician into the lower part (9a). Close the medication nebulizer by turning the upper
part (9c) clockwise.
5. Assemble the desired accessories as shown on the drawing (picture 1) (page 1).
6. Sit in a comfortable position while holding the nebulizer, place the mouthpiece in your mouth or use the nasal prong
or the mask. Start the unit by turning the switch on (3). Drug delivery to the airways can be maximised by coordinating
breathing with the intermittent closure of the drug saving device (8). Close the hole of the drug saving device (8) with
your finger and gently inhale as deep as possible. Hold your breath for a moment in order to allow the inhaled aerosol
to deposit; then slowly breath out. Whilst holding your breath, remove the finger from the drug saving device (8) to
minimise drug wastage.
The drug saving device (8) should not be used if you require continuous nebulization especially
with children or disabled persons.
7. When the treatment is finished, turn off and unplug the unit. Before reusing, ensure that it has cooled
down to room temperature.
8. It may happen that during the use of the nebulizer visible humidity deposits form in the connection
tube (6), disconnect the tube from the nebulizer and let it dry using the compressor air flow.
ACCESSORIES -TECHNICAL FEATURES
Nebulizer RAPIDFLAEM 4 (suitable for intensive use)
The RAPIDFLAEM 4 is a professional, durable and rapid delivery nebulizer suitable for patients with chronic pathologies
especially when costly drugs are used. The constant average size of the aerosol particles delivered by the RAPIDFLAEM
4 nebulizer makes it suitable for treatment of both the upper and the lower respiratory tract. It features a valve system
that is automatically controlled by the patient's respiratory rhythm. During inspiration, the inspiratory valve (A) in the
nebulizer opens to allow the intake of additional air which increases the amount of nebulized drug available to the patient,
while the exhalation valve (B) in the mouthpiece (10) is closed. The patient can keep the mouthpiece in the mouth when
breathing out, as the exhalation valve (B) automatically opens when exhaling and the inspiratory valve (A) is closed, which
also reduces the drug nebulization and minimises the release of nebulized drug into the environment.
Essential oils or balsamic substances should not be used with the nebulizer.
Technical features
- Made from non toxic materials
- Disinfect by boiling or, when used in clinics or hospitals, autoclave at 121°C max. (1.2 bars) for maximum 25 minutes.
- Capacity:
max. 7 ml
- * Aerosol output: 0.65 ml/min approx
MMAD 2.45 µm
- * Particle:
*Average values measured with 0.9% saline solution.
Certified with TSI Aerosizer 3220 computerized laser system in compliance with Flaem internal procedure.
Professional aerosol therapy unit
Use the unit only as described in this instruction manual.
NEBULFLAEM
5
DRUG SAVING
DEVICE