Before Returning For Repairs - DSR INC-800A Guide D'utilisation

Masquer les pouces Voir aussi pour INC-800A:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PROBLEM
The LCD display shows:
BAD BATTERY and
beeps four times, then
shows CONNECT
BATTERY.
There is nothing showing
on the digital display.
The charger is making an
audible clicking sound.
Charger makes a loud
buzz.

14. BEFORE RETURNING FOR REPAIRS

For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT SHIP
UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA) number
from Customer Service at Schumacher Electric Corporation.
POSSIBLE CAUSE
The battery is bad or
sulfated.
The charger is not
plugged in.
No power at the receptacle.
Poor electrical connection.
Circuit breaker is cycling.
Severely discharged
battery, but otherwise it is
a good battery.
Transformer laminations
vibrate.
If these solutions do not eliminate the problem,
or for more information about troubleshooting,
contact customer service for assistance:
services@schumacherelectric.com
www.batterychargers.com
or call 1-800-621-5485
Monday-Friday 7:00
In the case of a severely discharged
battery, the charger will go into
abort mode. If, after the output
turns off, the battery voltage drops
to under 0.2 volts, the charger will
reset to the default settings and the
display will show 12V FAST on the
top line and CONNECT BATTERY
on the bottom line.
Plug the charger into an AC outlet.
Check for open fuse or circuit
breaker supplying the AC outlet.
Check the power cord or extension
cord for a loose fitting plug.
The output clamps are overloaded,
due to a shorted cable or clamp,
or there is too much power being
drawn from the AC line. Diagnose
and correct the shorted condition, or
unplug anything else that is on the
same AC line as the INC-800A.
The battery may not want to accept
a charge due to a run-down state.
Allow charging to continue until
battery has a chance to recover
sufficiently to accept a charge.
If more than 20 minutes, stop
charging and discard the battery.
No problem; this is a normal
condition.
to 5:00
CST
am
pm
• 9 •
SOLUTION

Publicité

Table des Matières