7.2.6 Integrated path measuring system

Positioning accuracy: +/- (0.025 + 0.01 x L*) mm
* L = Stroke of the linear axis in m
The reference temperature for the specification (positioning accuracy) is 20 °C accor-
ding to DIN EN ISO 1:2002-10.
2
5
4
3
1
8
7
6
View Side:
Connection side
Pin contact
Inverted with index signal
PIN 1
PIN 2
PIN 4
PIN 5
PIN 6
PIN 7
Further information can be obtained from the original documentation enclosed with the path
measuring system.
74
74
74
red
orange
brown
black
yellow
green
Signal
A
B
+UB
GND
/A
/B