EINHELL RT-PG 5000 DD Mode D'emploi D'origine page 18

Générateur de courant à moteur diesel
Masquer les pouces Voir aussi pour RT-PG 5000 DD:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
Anleitung_RT_PG_5000_DD_SPK7:_
GB
12. Troubleshooting
Fault
Engine does not start
Generator has too little or no
voltage
18
09.10.2009
11:04 Uhr
Cause
- Oil pressure switch tripped (red LED
(Fig. 2/Item 8))
- No diesel fuel
- Mechanical switch (Fig. 5/Item A)
set to "STOP"
- Diesel filter blocked
- Air filter dirty
- Diesel filter frozen due to low out
door temperature
- Controller or capacitor defective
- Overcurrent circuit-breaker has
tripped
- Carbon brushes in generator worn
Seite 18
Remedy
- Check oil level, top up with engine
oil
- Top up with diesel fuel
- Set mechanical switch to "RUN"
- Clean or replace the diesel filter
- Clean or replace the air filter
- Proceed as described in the point
entitled "Winter operation"
- Contact authorized after-sales
service outlet
- Press the switch and reduce the
consumers
- Contact authorized after-sales
service outlet

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

41.523.54

Table des Matières