OPERATOR:
The person/s charged with operating the
machine for its intended purpose.
CLASSIFICATION OF OPERATORS
The operator can be classified according
to two main categories, which, in some
cases, refer to one single person:
The
operator
equipment operation has the duty to:
Start up and monitor the
o
machine's automatic cycle;
Carry out simple setting
o
operations;
Remove
o
equipment stop not implying
breakings of members but
simple operating anomalies.
Maintenance technician a technician
trained by an authorised
centre, capable of working on the
machine's mechanical and electrical
components with its guards open to
make adjustments and to service and
repair it.
USER
Body or person legally responsible for the
equipment.
3.1.2
Personal safety information
The MAHLE ACX 150/250 A/C service
station is particularly simple and reliable
due to its adjustments and functions.
When used correctly it presents no
hazard for the operator, provided he
observes the following general safety
instructions and that the service station is
regularly
serviced
maintenance/use
equipment's safety). Before operating the
service station for the first time, read
charged
with
the
the
causes
MAHLE
(incorrect
compromise
the
EN | 4 | ACX150/250 | Safety conditions
these instructions carefully. If any part of
the instructions is unclear, contact your
reseller or MAHLE.
This service station may be used by only
one equipment operator, familiar with A/C
and refrigeration systems and the hazards
associated with refrigerants and high
pressure equipment.
WORKPLACE: The station can work with
both R134a and R1234yf (the two
refrigerants cannot be stored within the
of
station at the same time).
Refrigerant
flammable refrigerant.
Nonetheless, although refrigerant R134a
is not defined as flammable, mixtures of
air or oxygen with R134a may become
flammable
conditions.
The
equipment
outdoor or in a well-ventilated location
(at least 1 air change per hour). The
workshop has to be equipped with
ventilation systems able to ensure air
change in every environment area or
carry
out
opening the areas.
Use the equipment away from heat
sources or hot surfaces. The equipment
must not be used in explosion risk
environments
atmospheres). Before using it, put the
equipment on a levelled plane and secure
position, blocking it with suitable wheel
stops.
Do not expose the tool to direct sunrays,
heat sources, rain and jets of water. Do
not smoke near the equipment and during
operations (keep at a distance of at least
1 m).
R1234yf
is
defined
under
very
must
be
periodical
ventilation
(potentially
as
particular
operated
by
explosive
© MAHLE