Technical Data
Power supply
AC voltage 230 V / 50 Hz, single-phase
Range approx. 195 V – 250 V / 50 – 60 Hz
Output current (charging current battery)
Charging current max. 30 A, arithmetic mean value, electroni-
cally controlled according to the IUoU charging reference line
Output voltage
DC voltage 12 V
Charging process
Automatic
Automatic switching (main charging process)
OFF at a battery voltage of 14.4 V, charging current < 27 A
Automatic switching (afterloading phase)
10 hours constant 14.4 V for gel batteries / AGM
4 hours constant 14.4 V for liquid electrolyte batteries
Automatic switching (trickle charging)
Trickle charging constant 13.8 V
Temperature-dependent control (optional)
The values of the automatic switching device refer to a battery
temperature of 20 °C. If a temperature sensor is used with the
battery, these values will vary in accordance with the battery
temperature.
High temperature
–> reduction of the threshold values
Lower temperature –> higher threshold values
Application
Parallel mode, general charging mode
Temperature
Ambient temperature from -25 °C to +35 °C
During operation, the casing may heat up to around 75 °C
Cooling
By convection
Configuration
In accordance with the VDE provisions and the device safety
law
Use
To charge the batteries with 12 V rated voltage and a capacity
of 100 – 300 Ah

Dimensions / weight

Casing
Aluminum, painted, ventilated
Length
302 mm (without feet)
Width
173 mm (without feet)
Height
100 mm
Weight
3 kg (30 N)
10
Charging reference line
HL = Main charging phase
NL = Afterloading phase
EL = Trickle charging
U[V]
I[%]
I
100
14.4
13.8
50
U
0
0
HL
Fig. 2: Charging reference line (basic curve)
The right to effect technical modifications is reserved!

Troubleshooting

Error
The battery does not charge.
The maximum charging cur-
rent is not reached.
If these measures do not solve the problem, please con-
tact the Truma Service Centre.
NL
E L
t[h]
Rectification
Check all connections from
the automatic charger to
the battery, ensure that they
are connected to the right
terminals. Unplug the cold
device plug on the device
then plug in again. Check all
fuses and the mains supply
connection.
The device is too warm, en-
sure better ventilation of the
device.