Fault
Cause
The generator
Too much oil in the engine.
tends to go off.
Load is over 6,2 kW.
Only TEC60:
Carburettor is not receiving any petrol.
Air intake is blocked.
Inverter is damaged.
Electromagnet (inverter) is blocked.
Air filter is dirty.
The generator is
Inverter is damaged.
running but does
RPM too low.
not supply any volt-
age.
The generator
The stepper motor is faulty or the cable is
starts up very fast
disconnected.
and then the
"GENERATOR
ALERT" message
appears.
The generated
Inverter is damaged.
voltage is unstable.
EN
Troubleshooting
Remedy
➤ Drain the oil.
➤ Switch off the consumers.
➤ Clean the carburettor.
➤ Check the air filter (see chapter
"Servicing the air filter" on
page 24).
➤ Contact an authorised workshop.
➤ Check the output wiring connec-
tion
➤ Contact an authorised workshop.
➤ Contact an authorised workshop.
➤ Contact an authorised workshop.