Servicing the generator
10.5
Servicing the air filter
!
WARNING! Danger of explosions
Do not use diesel oil or solvents with low boiling points for cleaning the
air filter. They could ignite or explode.
A
NOTICE!
Never leave the engine running without an air filter. Otherwise this
quickly wears out the engine.
I
NOTE
If the air filter is dirty, the air flow to the carburettor is reduced. Check the
filter regularly so that the carburettor can function properly. Check this
more frequently if the generator is being used in particularly dusty
environments.
➤ Prepare the maintenance work and pull the generator out of the housing slightly:
see chapter "Preparing maintenance work" on page 22.
➤ Remove the screws (fig. 7 1, page 5) and the filter cover (fig. 7 2, page 5).
➤ Remove the screw (fig. 7 3, page 5).
➤ Take out the air filter (fig. 7 4, page 5).
The air filter consists of two parts: a sponge filter and a paper filter.
➤ Check the condition of both parts of the filter carefully. Replace the damaged
filter parts.
➤ Clean the undamaged filter parts; see the following section.
➤ Finish the maintenance work, see chapter "Finishing maintenance work" on
page 23.
Cleaning the sponge filter
➤ Wash the sponge with a neutral detergent solution and rinse it thoroughly.
➤ Leave the sponge to dry completely.
➤ Soak the sponge in fresh engine oil.
➤ Squeeze out the excess oil.