6.3 Flashing light

10 W - 24 V bulb MAXIMUM - use of a bulb with power greater than 10 W - 24 V
can cause motorisation malfunctions.
Operation of the flashing light
The light flashes while the gate is moving.

6.4 Area lighting

This accessory is not compatible with solar power.
Only use halogen or incandescent bulbs for area lighting, 500 W maximum.
Area lighting operation
Area lighting comes on each time the motor is switched on. It goes out automatically 1
minute and 30 seconds a er movement has finished.

6.5 Backup battery

This accessory is not compatible with solar power.
The backup battery ensures the operation of the gate in the event of an electrical power
failure.
To increase the operation time of the battery during use, the wired controls are
deactivated and the gate can only be controlled using the remote controls and the radio
control points.
The
indicator light flashes (1 pulse) when the motor is battery-operated.

Battery technical data

• Battery life: 10 continuous cycles or 24 hours on a gate in perfect condition.
• Optimum charging time before using the battery: 48 hours.
• Service life: 3 years.
To ensure an optimum battery life, switch the gate's electric power supply off at least
3 times a year to run a number of cycles using the battery.

6.6 Key contact

This accessory is not compatible with solar power.