Automatic Closing; Activating Automatic Closing; Deactivating Automatic Closing - Returning To Standard Operation - SOMFY EXAVIA 500 Manuel

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

AUTOMATIC CLOSING

8
WARNING
For operation in automatic mode or remote control, photoelectric cells must be installed. In automatic mode, the motorisation oper-
ates in at least one direction with no intentional activation by the user.

8.1 Activating automatic closing

Automatic closing can only be activated if the photoelectric cells are connected and recognised by the motor's control electronics.
1
>2s
Press the
button on the
control electronics for 2
seconds.
The indicator light
on.
4
Keep button 2 on the remote control depressed until the
light goes out and is then lit constantly.

8.2 Deactivating automatic closing - returning to standard operation

To deactivate automatic closing mode and return to standard operation, repeat steps 1, 2 and 3 above then in step 4, briefly press
button 2 of the remote control, indicator light
Press button 1 on the remote control 3 times.
14
EN - Replacing the EXAVIA 500 / WISPA 800 / SGS 201SGS 400 / SGS 501 electronic unit - SOMFY
2
Position the remote control on the
control electronics target.
comes
flashes.
3
Keep button 1 of
the remote control
depressed until the
indicator light
flashes.
5
indicator
When you release button 2, indicator light
press button 1 on the remote control 3 times.
The
indicator light remains lit.
Automatic closing is activated.
Once step 3 has been
carried out, you can
carry out the following
steps
remotely
(without placing the
remote control on the
target).
x3
flashes;