4. QUICK COMMISSIONING

4.1. Memorising the Keygo io remote controls for
operation in complete opening - Fig. 13
If this procedure is carried out using a channel which has already been
memorised, this channel will be cleared.
1) Press the "PROG" button for 2 s.
The screen displays "F0".
2) Press the outer le and right buttons on the remote control together.
The remote control indicator light flashes.
3) Press the button of the remote control that will open the gate fully.
The screen displays "Add".

4.2. Auto-programming

Auto-programming allows the gate's speed, max. torque and slowdown
zones to be adjusted.
Attention
• It is essential to perform the auto-programming procedure for
the gate's travel when commissioning the motorisation.
• The gate must be in the intermediate position before auto-pro-
gramming is started.
• During auto-programming, the obstacle detection function is not
active. Remove any objects or obstacles and do not allow any
persons near or inside the operating range of the motorisation.
• - To carry out an emergency stop during auto-programming,
use a programmed remote control or press one of the interface
buttons.
4.2.1. Starting auto-programming - Fig.14 and 15
1) Press and hold the "SET" button for 2 s.
Release the button when the screen displays "H1".
2) Press "OK" to start auto-programming.
Auto-programming must start with the gate being opened.
The gate performs two complete Opening and Closing cycles.
Attention
• If auto-programming starts with a gate closure, stop the au-
to-programming in progress, move the cursor indicated in Fig.
15 then start auto-programming again.
• If auto-programming is correct, the display indicates "C1".
• If the auto-programming cycle has not completed correctly, the
display indicates "H0".
Attention
Once installation is complete, it is essential to check that the
obstacle detection system complies with annex A of the standard
EN 12 453.
It is possible to access auto-programming mode at any time including
when the auto-programming cycle has already been completed and
the display indicates "C1".
Auto-programming can be interrupted by:
• activating a safety input (photoelectric cells, etc.)
• the appearance of a technical fault (thermal protection, etc.)
• pressing a control button (motor electronics, memorised remote
control, wired control point, etc.).
In case of interruption, the display indicates "H0" and the motor returns to
"Awaiting setting" mode.
In "Awaiting setting" mode, the radio controls operate and the gate
moves very slowly. This mode must only be used during installation. Au-
to-programming must be successfully performed before the gate can be
used normally.
During auto-programming, if the gate is stationary, pressing "SET" will
exit auto-programming mode.
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.

5. OPERATING TEST

5.1. Complete opening operation - Fig. 16

5.2. Obstacle detection operation

Obstacle detection when opening = stop + partial reversal.
Obstacle detection when closing = stop + complete reopening.

5.3. Operation of the photoelectric cells

With the photoelectric cells connected to the dry/Cell contact (ter-
minals 19-20) and Cell safety input parameter P07 = 1.
• Cells obscured with gate open = the gate cannot be moved until the
operating mode changes to deadman operation (a er 3 minutes).
• Cells obscured when opening = the state of the cells is not taken into
account and the gate continues to move.
• Cells obscured when closing = stop + complete reopening.

5.4. Safety edge operation (closing only)

Activation of the safety edge when closing = stop + complete reopening.
5.5. Specific operation
See the user booklet.

5.6. User training

All users must be trained on how to safely use this motorised gate (stand-
ard use and unlocking principle) and on the mandatory periodic checks.

6. CONNECTING ADDITIONAL DEVICES

6.1. General wiring diagram - Fig. 17

Terminal
Connection
1
L
230 V power supply
2
N
3
L
Transformer primary
supply output
4
N
5
N
230 V lighting output
6
L
7
Conductor
Antenna
8
Braid
9
Contact
PEDESTRIAN/CLOSING
control input
10
Shared
11
Contact
COMPLETE/CLOSING
control input
12
Shared
Auxiliary contact
output
13
Contact
14
Contact
Safety input 3 - pro-
grammable
15
Shared
16
Contact
Safety test output
17
Contact
Safety input 2 - safety
edge
18
Shared
19
Contact
Safety input 1 - Cells
20
Shared
21
24 V
Safety device power
supply
22
0 V
EN
Comments
NB: Earth connection
available on the motor
flange
Max. power 500 W
Protected by 5A time-de-
lay fuse
Programmable (parame-
ter P37)
Programmable (parame-
ter P37)
24 V, 1.2 A outage
Safety Extra Low Voltage
(SELV)
Only compatible with a
dry contact safety edge
BUS compatible (see
parameter table)
Used to connect RX cell
Permanent if autotest
not selected, controlled if
autotest selected
6