Leica DIGICAT 100 Manuel De L'utilisateur page 65

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Data output
Wireless Communication with DIGICAT 200GIS
Typical Serial Data String Output:
DV200SN123456SV2.01TM00:00DT00/00/00CM05ST0BT2MD0SS02UMMDP---
Each Characher is ASCII.
Data output
Range
DV
000 to 999
SN
000000 to 999999
SV
0.00 to 9.99
TM
00:00 to 23:59
DT
00/00/00 to
31/12/99
CM
00 to 15
ST
0 or 1
BT
0 to 9
MD
0 to 3
SS
01 to 30
UM
M or I
DP
0.30 to 3.00 or ---
Typical Value
200
123456
3.01
08:30
01/12/06
12
0
7
3
16
M
125
DIGICAT 100/200
Comment
Digicat Unit Identifier
Serial No.
Software Version
Time: hh:mm
(default = 00:00 no RTC fitted)
Date: dd/mm/yy
(default = 00/00/00 no RTC fitted)
Number of Months until next Cali-
bration (00 to 15)
Self Test: 0 = Pass, 1 = Fail
Battery level: 0 = Empty, 9 = Good
Mode: 0 = Power, 1 = Radio,
2 = 8 kHz, 3 = 33 kHz
Signal Strength: 01 to 30
Units of Measurement:
M or I (Metres or Imperial)
Depth: 0.30 to 3.00,
depends on UM. Displays Depth in
33 kHz Mode, else ---
63

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Digicat 200

Table des Matières