Technical Data - Aventics HF02-LG Instructions De Montage

Masquer les pouces Voir aussi pour HF02-LG:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
AVENTICS | HF02-LG/HF03-LG | R412008260–BAL–001–AH | English
10
Supply plate
11
Cross recessed screws DIN EN ISO 4757- Z1
Product identification
Observe the product information on the product and packaging.
5
Equipment variants
The HF02-LG/HF03-LG valve terminal system can be equipped
with base plates for single solenoid and double solenoid. The
following combinations are possible:
W
Max. 32 base plates, for single solenoid valves (only HF03-LG)
W
Max. 16 base plates, for double solenoid valves
W
Combination of base plates for single solenoid and double
solenoid valves
O
Base plate combination options for single solenoid and double
4
solenoid valves (see
Important notes on equipment
O
If the equipment is combined, the base plates for double
solenoid valves must be installed before the single solenoid
ones.
O
Note the marking for base plates for single solenoid valves
2
(see
).
O
If a single solenoid valve is installed on a base plate for double
solenoid valves, the corresponding connection for solenoid 12
remains unused.
6
Assembly
Electrical voltage and high pressure
Danger of injury from electrical shocks and sudden pressure
drops.
O
Make sure the system is not under pressure or voltage before:
– removing or connecting plugs,
– disassembling the system or
– exchanging individual components.
Risk due to incorrectly mounted device
An incorrectly mounted device may result in uncontrolled
movements that could damage other system parts. The
mounting of the VS can become unstable due to vibrations
occurring during operation.
O
Make sure that all components are attached to a base plate
that is securely fastened to the machine or a mounting
plate.
O
If more than 16 pieces are fitted to the VS, do not mount it on
a hat rail.
).
DANGER
NOTICE
Extending the VS HF02-LG/HF03-LG
Observe the assembly sequence!
O
First install the base plates for double solenoid valves, then
those for single solenoid valves.
3. Loosen the hexagonal socket-head screws (7) and remove the
P end plate (6).
4. Screw in the tie rod extension (3) flush with the tie rod (2).
5. Insert the seals (5) in the base plate(s) (4).
6. Place the base plate(s) (4) on the tie rod extension (3).
Make sure the seals have been inserted correctly (5).
7. Mount the right P end plate (6) and tighten the hexagonal
socket-head screws (7)
(Tightening torque: 3.0 + 0.5 Nm).
8. Place the valve (9), supply plate (10) or blanking plate (8) on the
base plate(s) (4) and screw them in with the crossed recessed
screws DIN EN ISO 4757 - Z1 (11) (tightening torque:
1.1 + 0.2 Nm, tightening speed: 500 rpm
Installing the mounting bracket
If more than 16 base plates are to be mounted in the HF03 LG and
if the VS is subject to oscillations and vibration during operation, 2
mounting brackets (see material number R412008245) must be
installed to stabilize it. The VS does not need to be disassembled to
do this.
1. Turn off the operating voltage and compressed air supply.
2. Slide the two mounting brackets into the recesses between
two base plates on the rear of the assembled VS until flush,
and firmly screw each of the brackets to the base with one
screw (e.g. with M5 x 10 DIN 912, tightening torque
5,5 + 0,5 Nm).
Make sure during assembly that the mounting brackets
have been symmetrically distributed on the VS.
7
Disposal
Dispose of the packaging and used parts in accordance with the
regulations of the country in which the extension kit has been used.
8
Accessories/spare parts
Accessories and replacement parts can be found in the online
catalog or the operating instructions.
9

Technical data

For further technical data, please see the online catalog
at www.aventics.com/pneumatics-catalog.
4
-1
).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour: