Function Priority

Simulated Land Line Priority

If the equipment connected to the LI terminals (e.g. Control panel) tries to engage the line, this Device will interrupt any ongoing
communications (SMS or ContactID) in order to send the calls generated by the device. This Device will restart the interrupted commu-
nications when the equipment disengages the line.

SMS or Contact ID Priority

If the equipment connected to the LI terminals (e.g. Control panel) is using the GSM Network (through this Device) when an SMS or
ContactID associated event occurs, this Device will interrupt the ongoing call and send the respective SMS message or ContactID report.

ContactID Event Priority

If several events occur contemporarily, the respective messages will be sent in chronological order. If an event is associated with a
ContactID report and an SMS communication, priority will be given to the ContactID report.
This Device has 4 outputs programmable as Automatic (outputs with this attribute will activate in response to the associated events)
or Remote Control (outputs with this attribute can be activated manually from remote locations by means of SMS messages or calls
from enabled telephone numbers).

Activating/Deactivating Automatic Outputs

The PGM outputs can be activated automatically by the following events:
 Land line trouble (line down)
 GSM Module trouble
 GSM Network trouble (Limited/No Service)
 Power supply trouble (external power supply or battery)
 Incoming call
 Outgoing call
 Contact ID call
 Enablement of remote programming
 Fail to communicate for internal events (FTC)
, , , , , Once an output has been activated automatically, it will not restore its state until all the causes of activation clear.

Activating/Deactivating Remote-control Outputs

, , , , , ATTENTION - You must wait at least 5 minutes, after the powering-up the Device, before the outputs can be
activated/deactivated from remote locations.
The OC outputs can be programmed as BISTABLE (activated/deactivated by means of an SMS text message or Remote Control
number) or MONOSTABLE (activated by means of SMS text messages or Remote Control numbers). Once a Monostable output
has been activated, it will not deactivate until the programmed ON Time expires. Each output can be set up to provide a feedback signal
(ring or SMS text message).
, , , , , For further information regarding the terms "Access Code" and "Output Label" (used in the following section), refer
to the "Outputs Page" in the "PROGRAMMING THE DEVICE" section.

Bistable Outputs (for appliance management)

Bistable OC outputs can be activated in 2 ways.
1. By sending a case sensitive SMS text message containing the respective Access Code, placed between pound signs (#), and the
Output Label (e.g. GATE) followed by =ON, as follows:
2. By sending a cost-free call from a preset Remote Control number. This Device will activate the respective output without answering the call.
, , , , , Bistable OC outputs can be deactivated by sending a case sensitive SMS text message containing the respective Access Code
placed between pound (#) signs and Output Label (e.g. GATE) followed by =OFF, as follows:
BGSM-G

ACTIVATING THE OUTPUTS

#ACCESSCODE#OUTPUTLABEL=ON (example: #AZ55#GATE=ON)
#ACCESSCODE#OUTPUTLABEL=OFF (example: #AZ55#GATE=OFF)
G
G
G
G
G
23