Installation; Clearances; Location; Installation Instructions For - Garland Master MSSR16 Instructions D'installation Et D'utilisation

Salamandres à infrarouge
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION

Clearances

Models (M, MS, MST)(SRC, SR16) are for installation in non-
combustible locations only with zero (0") sides and rear
clearance.
NOTE: Adequate clearance must be provided for servicing
and proper operation.

Location

Counter salamanders should be installed on a fi rm, smooth
and level base designed to withstand the weight of the fully
laden appliance. Any openings in the wall behind or beside
the appliance must be sealed.

Installation Instructions for

Range Mount Salamander

SAFETY
FIRST
USE PROPER
LIFTING TECHNIQUES
4
8
2
"X"
"X"
1
Page 6
3
6
7
5
~
1. Remove the front panel (5) by removing two (2), sheet
metal screws from the underside of the salamander.
2. With the back panel, (4), still attached to the uprights
(2&3) drop the uprights into the rectangular openings at
the rear of the range (1).
3. Fasten the uprights, (2 & 3) to the range with four, (4),
5/16" x 18 bolts and fl at washers. (6&7)
4. If the range is in a battery line-up, fasten units together
at the hole marked "X" with 1/4" x 20 bolts, nuts and
washers.
5. Reattach the front panel (5) to the salamander with sheet
metal screws previously removed.

Wall Mounted Salamanders

1. Each gas appliance must be located with respect to
building construction and other equipment so as to
permit access to the appliance, Such access and clearance
may be necessary for servicing and cleaning.
2. Salamanders intended for wall mounting are shipped
with the mounting kit already attached.
3. Provisions for gas connections, bottom or rear should be
taken into consideration.

Statutory Regulations

When checking gas pressure be sure that all other
equipment on the same gas line is on. A pressure regulator is
supplied as standard equipment with Garland salamanders.
Installation must conform to the National Fuel Gas Code ANSI
Z223.1 or latest edition and/or local code to assure safe and
effi cient operation.
Part # 1382684 Rev. 02 (11 Feb 2014)

Publicité

Chapitres

Table des Matières
loading

Table des Matières