Every Six (6) Months (Or once every
pool season whichever is shorter)
6.3.1
Nature
Mineral Cartridge
2
Replacement
The Nature
Fusion cartridge lasts six (6) months or one
2
pool season (whichever is the shorter length of time).
WARNING
Always turn pump off prior to installing or removing
any components from the pool's plumbing. Your
pump/filter system is operated under pressure and
pressure must be released before you begin to avoid
system damage or personal injury. Open the air relief
valve on your pool filter to release the pressure in the
system.
1.
Shut off the pool pump and filter.
2.
Close valves between filter and pool to
prevent pool draining.
3.
Turn large collar counterclockwise to remove
and lift off cap.
4.
Remove old cartridge and discard in
household trash. Insert the new cartridge
(see Section 4.3)
5.
Position cap flat on the vessel housing.

IMPORTANT

Make sure the o-ring is
secure in the groove on the vessel top, not
on the underside of the cap. Turn large collar
clockwise until it locks into place, do not over
tighten.
6.
Open any valves that were closed to isolate
the Nature
Fusion Soft.
2
|
Zodiac
Nature
Fusion Soft
Installation and Operation Manual
®
ENGLISH
6.4
Electrolytic Cell Cleaning - As
Needed
Depending upon water chemistry, occasional manual
cell cleaning may be necessary.
1.
Switch off the filter pump and chlorinator, close
necessary valves.
WARNING
Always turn pump off prior to installing or removing
any components from the pool's plumbing. Your
pump/filter system is operated under pressure and
pressure must be released before you begin to avoid
system damage or personal injury. Open the air relief
valve on your pool filter to release the pressure in the
system.
2.
Unplug the yellow connector from the vessel.
3.
Unscrew the electrolytic cell retaining ring and
remove the electrolytic cell.
4.
Look down into the electrolytic cell to see if there
is scale on the plates.
WARNING
To avoid personal injury when working with pool
chemicals, always wear rubber gloves and eye
protection, cover exposed skin, and work in a well
ventilated area. Use caution when choosing a
location to open and use chemicals as they may
damage any surface into which they come in contact.
If any chemical gets on your skin, rinse the area
immediately with water. If any chemical gets on your
clothing, immediately remove the piece of clothing
and rinse with water.
5.
Mix cleaning solution in a suitable plastic
container by adding one (1) part of hydrochloric
(muriatic) acid to ten (10) parts water. Note: To
avoid splash, always ADD MURIATIC ACID
TO WATER rather than water to muriatic acid.
Solutions stronger than 1:10 will damage the
electrolytic cell and void warranty. Submerge only
the plates of the electrolytic cell in the cleaning
solution. See Figure 18. Allow the cleaning
solution to dissolve the calcium deposits for
approximately five (5) minutes.
6.
Repeat the procedure if necessary. Take care to
avoid splashing the electrolytic cell terminals and
other equipment with the acidic cleaning solution.
Wash down any spills with plenty of fresh water.
To neutralize acid cleaning solution, add baking
soda (foaming will occur).