Control Valve Installation Options
Install between the inlet
and discharge side of
Install on the inlet
bypass plumbing
side of the vessel
Nature
Flow
Figure 5.
Example of Bypass Installation
9.
Fully open any closed valves, including the control
valve, and start the pump diverting water through
the new bypass.
10. Check the vessel and system for leaks.
11. Adjust control valve so that flow rate through the
vessel is between a minimum of 114 lpm (30 gpm)
and a maximum of 455 lpm (120 gpm).
3.6

Split-Return Installation

If the vessel is used with a water feature line system, it
must be installed in a split-return configuration or vessel
damage may occur.
1.
Make sure the pool pump is turned off.
2.
Install the Nature
2
cartridge..
Zodiac
Nature
®
Heater
Flow/Temperature/
Salinity Sensor
Fusion Soft
2
Flow
Flow/Temperature/
Salinity Sensor
|
Fusion Soft
Installation and Operation Manual
Optional ChemLink or
other ORP Control
Pool Return
3.
Locate a suitable section of pipe to install
the vessel that conforms to the installation
requirements outlined in Section 3.2.
4.
Install a 3-way valve in the return line to allow
water to be diverted/restricted to the Nature
Fusion Soft and water feature line.
5.
Fully open any closed valves, including the 3-way,
to allow unrestricted flow to the Nature
Soft and water feature line.
6.
Hand tighten all unions, sensors, and collars.
Be careful not to get finger caught between inlet
union and plug when tightening as this may cause an
injury.
FUSIONM
or
APUREM
or
PureLink
TM
or
Existing AquaPure
®
k
Power Pac
Pump
Filter
Pool Intake
Spa Intake
Spa Return
Fusion
2
CAUTION
2