Grounding and Bonding

A solid, copper # 6 awg (13.3 mm
recommended for connecting the control/power center to
a permanent earth ground connection that is acceptable
to the local inspection authority. Refer to your local
codes for the acceptable grounding wire gauge.
The Canadian Electric Code (CEC) requires pool
equipment to be bonded to each other. Check your
local codes to determine if the CEC and/or other local
installation codes are enforced by the Authority Having
Jurisdiction (AHJ). A solid, copper # 6 AWG (13.3
mm
) wire is recommended, per the CEC, for bonding
2
the power pack to a permanent bonding connection that
is acceptable to the local AHJ. Refer to your locally
enforced codes for the acceptable bonding wire gauge.
Attach the bonding point located on the bottom of the
chassis backplate to a common earth bonding point. Do
not use the power pack as the common bonding point.
Each piece of non-related pool equipment requiring a
ground should also be bonded to the common, approved
earth bonding point. Never ground a pool pump to the
chassis backplate.
J1 Connector,
Power Interface
Board
Ribbon Cable
Figure 8.
Installation of the User Interface
|
Zodiac
Nature
Fusion Soft
Installation and Operation Manual
®
) wire is
2
3.9
Installation of the Chlorine Generator
Device User Interface on an
AquaLink
®
1.
On the chlorine generator user interface board,
connect one end of the ribbon cable to the 16-pin
J1 connector as shown in Figure 8.
2.
Connect the other end of the ribbon cable to the
power interface 16-pin J1 connector.
3.
Attach the chlorine generator user interface board
to the bezel using the four (4) screws provided.
3.10 Connecting the Nature
Vessel and Flow/Temperature/Salinity
Sensor
ATTENTION INSTALLER: If the flow/temp/salinity
sensor is not installed properly, it may allow the
vessel to operate without water flow. This would
cause a buildup of flammable gases resulting in
FIRE or EXPLOSION.
Mount as shown in Figure 9. This will result in
the most reliable operation.
IMPORTANT! Anytime the flow/temp/salinity
sensor is connected or disconnected and
reconnected, the AC power to the unit must be
turned off and back on (Cycle Power). If power is
not cycled, unreliable operation of the flow/temp/
salinity sensor will result.
J1 Connector,
User Interface
ENGLISH
Page 17