Technical Data; Specified Conditions Of Use - Güde GPS 40A Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
ENGLISH
20

Technical Data

Plasma cutter
Art. No
U
Rated input voltage AC Current
1
U
No-load voltage
0
I
/ U
Performance range (Welding current / Load voltage)
2
2
X
Switch-on time
The ratio of given duration time/the full-cycle time. *
I
Maximum rated input current
1max
I
Maximum effective input current
1eff
Degree of protection
IP21S
Insulation class
Class H
Compressed air (Flow rate, Pressure)
Material thickness max.
Weight
* The ratio of given duration time/the full-cycle time.
Switch-on time determined at 40°C using simulation
control elements and how to use the appliance
properly. Abide by all the safety measures stated in
the service manual. Act responsibly toward third
parties.
The operator is responsible for accidents or risks to
third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Class A (IEC 60974-10):
If you intend to use the apparatus in residential
surroundings supplied by the low voltage mains
supply, an electromagnetic filter may be required
to suppress electrical disturbance to a level where
they will no longer be a nuisance to the user.
The apparatus may be used in industrial or other
areas where power is not supplied by municipal
LV mains.
Class A apparatus are not intended for use in
residential areas where power is supplied via
municipal LV mains, since unfavourable power
conditions may cause interference.
As a user, you must make sure, after consultation
with your energy provider, if necessary, that your
Read and understand the operating
instructions before using the
appliance. Familiarise with the
I
= 40 A / U
= 96 V
2
2
I
= 26 A/ U
= 90,4 V
2
2
I
= 20 A / U
= 88 V
2
2
point of connection on which the machine is to be
operated meets the requirements above.
The user is responsible for faults arising from the
cutting.

Specified Conditions of Use

The plasma cutter with constant voltage characte-
ristic may only be used to cut electrically conductive
metals using air.
Only use the flame-cutting torch supplied.
Ambient temperature -10 °C - +40 °C
Relative air humidity max. 50 % (40 °C), 90% (20 °C)
Altitude above sea level max. 1000 m
The ambient environment must be free from
abnormal amounts of dust, acids, corrosive gases or
substances.
Respecting technical data and safety precautions.
Do not use this product in any other way as stated
for normal use. Not observing general regulations
in force and instructions from this manual does not
make the manufacturer liable for damages.
Please note that our equipment has not been
designed for commercial, craft or industrial use. If the
equipment is used in commercial, craft or industrial
operation or for similar activities, we cannot assume
any liability.
GPS 40A
20063
230 V
370 V
15 A/86V - 40A/96V
25 %
60 %
100 %
30 A
15 A
IP 21S
H
40-180 l/min, 5 bar
12 mm
7,48 kg

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

20063

Table des Matières