12. Technical Data

The COMO B.20, certifi ed in compliance with DIN-EN 13240 and Art. 15 a B-VG
(Austria), can only be operated when the fi re box is closed. Conforms with the DIBt
(Deutschen Institut für Bautechnik/German Institute for Building Technology) approv-
al criteria for direct vent fi replaces for solid fuels. Multiple connections to the chim-
ney are possible, see point 4. "Connection of Multiple Devices in Direct Vent
Operation".
DIBt approval number: Z-43.12-396 - Typ FC61x
The following data applies to the chimney characteristics in accordance with
EN 13384-1 / 2:
Combustion Values*
Nominal Thermal Output
Room heating output
Exhaust gas temperature
Waste Gas Outlet Temp.
Waste Gas Mass Flow Rate
Min. Supply Pressure at Nominal Thermal Output**
Effi ciency
CO content
Particulate
OGC
NO
X
Min. required combustion air volume
Depending on the insulation of the building, the nominal thermal output of 6,5 kW
indicated on 25 - 90 m² (subject to change).
Dimensions:
Stove
Fire box
Weight (Ceramic / Soapstone)
Flue pipe diameter
Pipe diameter of HASE ventilation system**
Front view:
Wood
6,5
kW
7,0
kW
227
˚C
272
˚C
6,3
g/s
12
Pa
83
%
≤ 1250
mg/Nm³
≤ 40
mg/Nm³
Top view:
≤ 120
mg/Nm³
≤ 200
mg/Nm³
26
m³/h
Height
Width
124 cm
60 cm
35 cm
31 cm
Side view:
60
19,5
Inst. of HASE air system
below
*
Test bench performance and values at 13% O
**
For separate air supply in low-energy hous-
es and insuffi cient combustion air supply in
the room where the stove is installed.
Depth
56 cm
32 cm
240 / 260 kg
15 cm
10 cm
en
2
Dimensions in cm
37