Wiring: 200–240 V, 3 Ф, 50/60 Hz
WARNING: Wait three minutes after disconnecting before servicing!
The diagram below shows wiring for a 200–240 V, three-phase VFD. A disconnect is included with the VFD for
200–240 V, 3 Φ. An EMI filter is not included with this VFD.
28
1 2 5 6
1 2 5 6
U
V
/T1
/T2
BLACK
GREEN/YELLOW
RED
BLUE
AC Input Wiring
3W plus GND
WWW.BIGASSFANS.COM
1 2 5 6
1 2 5 6
25 4 11
25 4 11
13A13B13C 14 30 16 17
13A13B13C 14 30 16 17
PE
W
L1
L2
/T3
BLACK
Motor Output Wiring
© 2018 DELTA T LLC
ALL RIGHTS RESERVED.
25 4 11
25 4 11
13A13B13C 14 30 16 17
13A13B13C 14 30 16 17
L1
L2
L3
L3
GREEN/YELLOW
RED
BLUE
3W plus GND