7b. Install main fan unit (direct mount)
The lower safety cables are a crucial part of the fan and must be installed correctly. If you have
any questions, contact Customer Service for assistance.
Attach the main fan unit directly to the angle irons with the Motor Unit Hardware. Do not rest the main fan unit
on the ground. Tighten the bolts to 40 ft·lb (54.2 N·m) using a torque wrench and 3/4" (19 mm) socket. After
securing the main fan unit to the angle irons, tighten all the bolts securing the angle irons to the roof structure to
40 ft·lb (54.2 N·m) using a torque wrench and 3/4" (19 mm) socket.
Motor Unit Hardware:
a. (4) 1/2-13 x 1-3/4" GR 8 Bolt
b. (8) 1/2'' Flat Washer
c. (4) 1/2-13 Nylock Nut
Motor Unit & Airfoil
Hardware Board
Drill a Ø9/16" (14 mm) hole in the center of each angle iron exactly
10" (254 mm) from the fan mounting holes as shown. Secure the
two lower safety cables (pre-attached to main fan unit) to the holes
with installer-supplied Grade 8 hardware. Tighten the bolts to
40 ft·lb (54.2 N·m) using a torque wrench and 3/4" (19 mm) socket.
Safety Cable Hardware (Installer-Supplied):
a. (2) 1/2-13 x 1-1/2" GR 8 Bolt
b. (4) 1/2" Flat Washer
c. (2) 1/2-13 Nylock Nut
10" (254 mm)
Ø9/16'' (14 mm)
5-1/2'' (140 mm)
Roof Structure
40 ft·lb (54.2 N·m)
5-1/2'' (140 mm)
Fan Mounting Holes
10" (254 mm)
WWW.BIGASSFANS.COM
a
b
Lower Safety
Cable
Ø9/16'' (14 mm)
© 2018 DELTA T LLC
ALL RIGHTS RESERVED.
40 ft·lb (54.2 N·m)
b
c
Main Fan
Unit
40 ft·lb (54.2 N·m)
a
b
b
c
Lower
Safety
Cable
15