Problem
When the equipment
is running, data are
incorrect or unreliable
Problems in monitoring
heart rate with the chest
band
Cause
A key is stuck on the
keyboard.
The equipment is near
sources of static (e.g.
appliances).
An internal connector
has been accidentally
disconnected.
There is an internal contact
inside the control panel.
The alternator belt is slack.
Other transmitters are
located nearby.
Strong sources of static
are located nearby.
The chest band is worn out.
The chest band is not in
proper contact with the skin.
The control panel
does not function properly.
The transmitter is damaged.
R
600 XT PRO
OTEX
Remedy
If the problem persists,
contact Technogym
Technical Support Service.
Move the equipment
elsewhere or move
the appliances.
Contact Technical
Technogym Support Service.
Contact Technical
Technogym Support Service.
Contact Technical
Technogym Support Service.
Move the equipment far
enough away so that
the signals do not overlap
(the minimum distance
between the two
equipments must be 31.5
inches, or 80 cm); otherwise
use the heart sensor.
Find the sources (such
as appliances) and move
them or the equipment.
Replace it by ordering it
directly from Technogym
Technical Support Service.
Moisten the inside of the
chest band with water.
Contact Technical
Technogym Support Service.
Replace the chest band
by ordering it directly
from Technogym Technical
Support Service.