Technical Data - HASE Asmara Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

11. Technical Data

The Asmara, certified in compliance with DIN-EN 13240 and Art. 15 a B-VG (Aus-
tria), can only be operated when the fire box is closed. Conforms with the DIBt
(Deutschen Institut für Bautechnik/German Institute for Building Technology) ap-
proval criteria for direct vent fireplaces for solid fuels. Multiple connections to the
chimney are possible, see point 4. "Connection of Multiple Devices in Direct Vent
Operation".
VKF-No.: 25257; DIBt approval number: requested / Typ FC41x und FC51x
The following data applies to the chimney characteristics in accordance with EN
13384-1 / 2
Combustion Values
Nominal Thermal Output
Efficiency
Particulate
CO content at 13% O2
Waste Gas Mass Flow Rate
Waste Gas Outlet Temp.
Min. Supply Pressure at Nominal Thermal Output
Min. required combustion air volume
Depending on the insulation of the building, the nominal thermal output of 6 kW
indicated on 20 bis 80 m² (subject to change)
Dimensions:
Height
Stove
156 cm
Fire box
49 cm
Weight (Ceramic=Natural stone)
¹Vertical flue pipe length
Flue pipe diameter
Pipe diameter of Hase ventilation system*
Front view
Ceramic/Natural stone:
Wood
6
kW
82
%
23
mg/m³
771
mg/m³
6,3
g/s
279
˚C
12
Pa
25
m³/h
Top view
Ceramic/Natural stone:
Width
Depth
41 cm
44 cm
25 cm
27 cm
202 kg
min. 33 cm
15 cm
10 cm
41
* For separate air supply in low-energy
houses and insufficient combustion air
supply in the room where the stove is
installed.
Side view
Ceramic/Natural stone:
Inst. of Hase air system
below: 20
Dimensions in cm
37

Publicité