Lighting The Fire; Adding Fuel / Heating At Nominal Thermal Output - HASE Asmara Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

7. Lighting the Fire

The firing up phase should be as short as possible,
since higher emissions can occur during this phase.
The slider settings described in Table 1 are recom-
mendations that were determined under confor-
mance testing conditions, in compliance with the
relevant standard. Depending on the weather con-
ditions and the draught capability of your chimney,
accordingly adjust the slider positions for your As-
mara to the local conditions.
NOTE!
The Asmara may only be operated when
the fire box door is closed; the fire box door
may only be opened to add fuel.
WARNING!
Never use spirits, petrol, or other flamma-
ble fluids to light the stove.
Lighting the Fire
Procedure
Position of Control
Elements
Switch air slider to the
Pull out the air slider out
heating-up position.
completely across the
red mark.
Pile up any remaining ash
and unburned charcoal
into the centre of the
Delhi
combustion chamber.
Open fire grate.
Pull fire grate slider all the
way out.
Place 4-6 small pieces
of wood with an approx.
Ø of 3-6 cm and max. 2
kg in the middle of the
burning chamber. Layer
these cross-wise on
top of each other. Place
approx. 0.5 kg of wood
shavings on top as a
firelighter.
Light the kindling/ignition
material.
Stop the heating phase
Push in the air slider
as soon as the fuel is
until the red marker is no
completely ignited.
longer visible.
Close fire grate.
Push in fire grate slider.
Tab. 1
8. Adding Fuel / Heating at Nominal
Thermal Output
More fuel should be added to the fire when the
flames from the previous burning off phase have
just gone out.
Adding Fuel / Heating at Nominal Output
Procedure
Position of
Control Elements
Adjust the combustion air.
Set air slider on position 2.
Close fire grate.
Push in fire grate slider.
Add two logs weighing
approx. 1.5 kg in total.
Place logs with the end to
the front of fire box. Only
add a single layer of fuel.
Tab. 2
CAUTION!
Please ensure that the logs are inserted
with sufficient distance (at least 5cm) from
the furnace window.
35

Publicité

Table des Matières
loading

Table des Matières