Technical Data - HASE Asmara Manuel D'utilisation

Masquer les pouces Voir aussi pour Asmara:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

12. Technical Data

The Asmara, certified in compliance with DIN-EN 13240 and Art. 15 a B-VG (Aus-
tria), can only be operated when the fire box is closed. Conforms with the DIBt
(Deutschen Institut für Bautechnik/German Institute for Building Technology) ap-
proval criteria for direct vent fireplaces for solid fuels. Multiple connections to the
chimney are possible, see point 4. "Connection of Multiple Devices in Direct Vent
Operation".
VKF-No.: 25257; DIBt approval number: Z-43.12-378 / Typ FC41x und FC51x
The following data applies to the chimney characteristics in accordance with EN
13384-1 / 2
Combustion Values*
Nominal Thermal Output
Efficiency
Particulate
CO content at 13% O2
Waste Gas Mass Flow Rate
Waste Gas Outlet Temp.
Min. Supply Pressure at Nominal Thermal Output
Min. required combustion air volume
*Test bench performance and values
Depending on the insulation of the building, the nominal thermal output of 6 kW
indicated on 20 bis 80 m² (subject to change).
Dimensions:
Height
Stove
156 cm
Fire box
49 cm
Weight without heat retaining block (Ceramic=Natural stone)
Heat retaining block (optional)
¹Vertical flue pipe length
Flue pipe diameter
Pipe diameter of Hase ventilation system**
Wood
6
kW
82
%
23
mg/m³
771
mg/m³
6,3
g/s
279
˚C
12
Pa
25
m³/h
Width
Depth
41 cm
44 cm
25 cm
27 cm
202 kg
67 kg
min. 33 cm
15 cm
10 cm
Front view
Ceramic/Natural stone:
41
Top view
Ceramic/Natural stone:
Side view
Ceramic/Natural stone:
20
Inst. of Hase air system
below
** For separate air supply in low-energy
houses and insufficient combustion air
supply in the room where the stove is
installed.
Dimensions in cm
37

Publicité

Table des Matières
loading

Table des Matières