Fronius Galvo 208-240 Instructions De Service page 49

Masquer les pouces Voir aussi pour Galvo 208-240:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fronius Galvo
Total harmonic distortion
Power factor (cos phi)
General Data
Maximum efficiency
CEC efficiency
Self-consumption at night
Self-consumption during operation
Cooling
Degree of protection
Dimensions h x w x d
Weight
Shipping dimensions w x h x d
Shipping weight
Permissible ambient temperature
(at 95% rel. humidity)
Permissible storage temperature
(at 95% rel. humidity)
Protection Devices
Ground fault monitoring
Stand-alone operation protection
Reverse polarity protection
Arc detection/interruption
Overtemperature
1)
DC voltage reduction at altitudes > 6561 ft. (2000 m)
2)
The maximum current from the inverter to the solar modules if an error occurs on the inverter
3)
Assured by electrical design of the inverter
4)
During normal operation
5)
4% tolerance for set switch-off time
6)
ind. = inductive
at 208 V
at 220 V
at 240 V
at 208 V
at 220 V
at 240 V
(Ground Fault Detector/Interrupter)
Operating point shift/active cooling
cap. = capacitive
1.5-1 208–240
2.0-1 208–240
< 4%
1
6)
0.85 -–1 ind./cap.
95.8%
94.0%
94.5%
94.0%
94.5%
94.5%
94.5%
0.7 W
0.9 W
0.9 W
8.0 W
Forced-air ventilation
NEMA4X
24.7 x 16.9 x 8.1 in.
628 x 428 x 205 mm
36.05 lbs.
16.35 kg
30.1 x 21.7 x 11.4 in.
770 x 550 x 290 mm
43.10 lbs.
19.55 kg
-40 °F – +122 °F
-40 °C – +50 °C
-40 °F – +158 °F
-40 °C – +70 °C
Internal GFDI
Integrated
Integrated
Integrated
49

Publicité

Table des Matières
loading

Table des Matières