The HAA9523S has been factory-set in single user mode with
Single user mode (command code: 8900)
Each output can only be operated by one user code. The user code must be 4 digits long. There are 10 000
possible code combinations. The code can be programmed directly into the user code locations 1, 2 and 3
respectively for the 3 outputs. Refer to "6. C) 1. Single user – Digits may be repeated" for more details. This
mode is always set with auto code entry in default. You do not need to press
4-digit user code.
NOTE: The system can be set for manual code entry with programming option 0 at location 82 if necessary.
Multi-user mode (command code: 8901)
Up to 100 individual codes will operate output 1 and 10 individual codes will operate output 2 and 3. The user
code can be 4 to 8 digits long. There are over 100 million possible code combinations. The user codes can be set
for auto or manual entry with programming options at location 82. Default mode is manual entry mode. Pressing
after code entry is required. Once the keypad is programmed in auto entry, the master code and the user
codes MUST consist of the same number of digits. Do not press
Default values
Default Comments
401
Output 1 in 1-second momentary
mode
501
Output 2 in 1-second momentary
mode
601
Output 3 in 1-second momentary
mode
70
After 10 successive false codes, the
keypad locks during 30 seconds
800
Door forced-open alarm disabled
NOTE: * All default values in multi-user and single user mode are exactly the same except the user code entry
mode.
Code entry limitation in multi-user mode due to duress code
The system comes with duress function for user code 1 in single user mode and all the user codes of group 1 in
multi-user mode. The duress code is automatically set by the system by taking the first digit of the user code and
adding or subtracting 2. To prevent other codes falling in the duress code, the first digit of a stored user code +2
or -2 is not allowed as a later user code entry.
Example: User code 56789 was stored in the system. User codes 36789 and 76789 are not allowed.
Set the system to single user mode
Set the system to single user mode with the command code 8900. The system will stay in that mode until it is
refreshed. Make sure the master code is 4 digits long.
MASTER
CODE
Set the system to multi-user mode
v2 15/11/2013
HAA9523S
as master code.
after entering the user code.
Default Comments
811
Output relay activation beep on
820
User code manual entry mode* (multi-
user)
821
User code auto entry mode* (single
user)
831
Pacifier tones on
90
No propped-up alarm
Single user mode enabled. Wait 2-3 seconds after
pressing
until you hear confirmation beeps.
8
in user code entry. Only enter the
VELLEMAN