NOTE: * Entering single user command code 8900 is not necessary if the keypad was already in single
user mode.
Cancel a wrong entry with
3. Operating the keypad – Taking the data programmed above and other default features as reference
a. To command an output, only enter the user code. Pressing
b. The personal master code is a super user code to command the outputs. This feature allows you to use
only one code to operate several keypads with the same master code but different user codes. Enter
the personal master code and validate with
c. The duress code does not need to be programmed. The keypad automatically determines the duress
code by increasing the first digit of user code 1 with two units.
Example: If user code 1 is 1234, then the duress code will be 3234. If user code 1 is 8321, then the
To command the duress function, enter the duress code.
NOTE: The duress code has 2 functions: it activates the duress output and at the same time it activates
output 1 as user code 1. The duress code can always activate or deactivate (in start / stop mode)
output 1, but cannot deactivate (reset) the duress output.
v2 15/11/2013
duress code will be 0321.
HAA9523S
Single user mode*
3289 stored as new personal master code and super user code
8321 stored as user code1 with duress code function for output 1
6854 stored as user code 2 for output 2
9270 stored as user code 3 for output 3
Output 1 set as momentary mode, 1 second
Output 2 set to start / stop mode
Output 3 set to start / stop mode
Keypad set to lock during 15 minutes after 10 successive false
codes
Exit programming mode. All above data stored and ready for use
or wait 10 seconds and retry.
Output 1 activates for 1 second
Output 2 starts or stops
Output 3 starts or stops
and the corresponding output number.
Output 1 activates for 1 second
Output 2 starts or stops
Output 3 starts or stops
Duress output activates (output switches to (-) ground) and