DGCI−...
Electrical installation
DGCI−...
Measuring system
Protection class (measuring system
incl. housing and connections)
Electrical connection
Interface
Baud rate
Linearity
Resolution
Supply voltage
Current consumption
Temperature coefficient
CE symbol (see conformity
declaration) è www.festo.com
Fig. 32
Festo DGCI−... 0801a English
magnetostrictive, contactless, absolute
measuring, digital
IP67 (with correctly fitted connector socket with
cable)
5−pin M9 round plug
CAN as per ISO/DIS 11898
[Mbit/s]
1
< ±0.02 % F.S. (min. ±50 ìm)
[mm]
0.005
[V DC]
24 (±25 %)
[mA]
100 typical
< 15 ppm / °C
in accordance with EU EMC directive