Internal Display; Target Priority Mode; Distance Display Units; Battery - Nikon COOLSHOT 40 Manuel D'utilisation

Masquer les pouces Voir aussi pour COOLSHOT 40:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Internal display

En
Es
Distance
Fr
Target mark
Pt
: Aim at the target you want to measure.
Position the target at the center of the reticle.
: Now measuring
* Because the internal display of this product is enlarged by the eyepiece, dust may sometimes be seen.
This will not, however, affect the measurement accuracy.

6. Target priority mode

This Nikon Laser Rangefinder employs First Target
Priority mode.
When measuring overlapping subjects, it displays the
distance of the closest subject.
10
Unit of measure (m/yd.)
Laser irradiation mark
Battery condition
: Appears while the laser is being irradiated for
a measurement.
Do not look towards the objective lens side
while this mark is shown.
: "Failure to measure" or "Unable to measure"

7. Distance display units

Measurement results are displayed in yards/meters.
(Factory default setting is yard.)
Yard
[
]
Meter
[
]
1. Turn on the power.
2. Press and hold the MODE button for more than two
seconds. After the display unit has switched, release
the button.

8. Battery

1. Type of battery
3V CR2 lithium battery x1
2. Inserting/replacing battery
2-1. Open the battery chamber cover
Rotate the battery chamber cover counterclockwise and remove it. It may not open easily due to its rubber
packing for water resistance.
2-2. Insert the battery/Replace the old battery with a new one
Insert a new battery correctly positioned following the indication seal inside the chamber. The [+] pole should be
positioned toward the inside of the chamber. If the battery is not inserted correctly, the Nikon Laser Rangefinder
will not operate. When replacing the battery, remove the old battery then insert a new one.
2-3. Close the battery chamber cover
Rotate the battery chamber cover clockwise to screw it into the body. It may not close easily due to the rubber
packing for water resistance, but continue to turn it all the way until it stops. Confirm that the cover is securely
closed.
3. Battery level indicator
* The battery condition mark in the internal display warns when the battery needs to be replaced.
Display
After power on, displays for 2 seconds only.
After power on, displays for 2 seconds only.
Displayed continuously.
Blinks. After blinking 3 times, automatically
powers off.
4. Battery life
Continuous operation: Approx. 1,400 times (at approx. 20°C)
This figure may differ according to conditions, temperature, and other factors such as target shape, color, etc. Use only
as a guide.
* The battery supplied with this Nikon Laser Rangefinder is for operation checking. Due to natural electrical discharge, the life
of this battery will likely be shorter than that noted above.
* If water enters the battery chamber due to submersion, dry the battery chamber well, then replace the battery.
Description
Sufficient power available.
Power getting low.
Prepare to replace the battery.
Low. Battery should be replaced with a new one.
Power exhausted.
Replace the battery.