Others
Symptom
The LAMP/COVER
indicator flashes.
The LAMP/COVER
indicator lights up.
The TEMP/FAN indicator
flashes.
The TEMP/FAN indicator
lights up.
Both the LAMP/COVER
and TEMP/FAN indicators
light up.
The control panel keys do
not function.

Warning Messages

Use the list below to check the meaning of the messages displayed on the screen.
Message
High temp.!
Probably use in high
altitude. Switch to high
altitude mode on? Yes V
No v
High temp.!
Lamp off in 1 min.
Frequency is out of range!
Please check Input-A
Signal Sel.
Cause and Remedy
• The lamp cover or the air filter cover is detached.
c Attach the cover securely (see pages 38 and 39).
• The lens protector does not open due to a problem.
c Slide the lens protector by hand, and then press the I/
• The lamp has reached the end of its life.
c Replace the lamp (see page 37).
• The lamp becomes a high temperature.
c Wait for 60 seconds to cool down the lamp and turn on the
power again.
• The fan is broken.
c Consult with qualified Sony personnel.
• The internal temperature is unusually high.
c Check to see if nothing is blocking the ventilation holes.
• The projector is used at a high altitude.
c Ensure that "High Altitude Mode" in the INSTALL SETTING
menu is set to "On."
• The electrical system breaks down.
c Consult with qualified Sony personnel.
• The control panel keys are locked.
c Unlock the control panel keys (see page 33).
Meaning and Remedy
• Internal temperature is too high.
c When using the projector at an altitude of 1,500 m or higher, set
"High Altitude Mode" in the INSTALL SETTING menu to
"On" (see page 36).
c If this message appears on the screen when using the projector
at normal altitudes, check to see if anything is blocking the
ventilation holes (exhaust).
• Internal temperature is too high.
c Turn off the power.
c Check to see if nothing is blocking the ventilation holes.
• This input signal cannot be projected as the frequency is out of the
acceptable range of the projector.
c Input a signal that is within the range of the frequency.
• The resolution setting of the output signal of a computer is too
high.
c Set the setting of output to XGA (see page 17).
• You have input RGB signal from the computer when "Input-A
Signal Sel." in the SET SETTING menu is set to "Component."
c Set "Input-A Signal Sel." correctly (see page 33).