within a maximum time of 10-15 seconds, otherwise the receiver will come
out of the programming mode.
f) To copy another key, repeat the sequence from step (a) and wait for the receiver to
come out of the programming mode (or disconnect the receiver from the power supply).
Note: Maximum protection from memory storage of foreign codes is
obtained by presetting the JP5 jumper closed and programming in
MANUAL mode or by means of the UNIPRO mod. programmer.
5.3) UNIPRO mod. Universal programmer (Fig.4-Fig.5)
To use the programmer, see the respective instructions. Transmitter -
Connect the UNIPRO programmer to the transmitter by means of the
UNITRC/UNIMITTO and UNIFLAT accessories supplied. Receiver -
Connect the UNIPRO programmer to the INTRIC receiver by means of the
UNIDA and UNIFLAT accessories supplied. The system will not support
the power input of the UNIPRO programer.
6) MAINTENANCE
The maintenance of the system should only be carried out by qualified
personnel regularly. The MITTO transmitters are supplied by two 3V
lithium battiers (type CR2016).The TRC transmitters are powered by a 12V
SW2
for CH2 output chanel
SW1
for CH1output chanel
Constant blinking.
Programming
and
The receiver enters the programming mode. If no memory storage takes place during the
Impulse output
subsequent 90 seconds, the receiver comes out of the programming mode. The combined
output relay remains picked up as long as the respective transmitter key is kept pressed.
SW2
SW1
2 blinks followed by a
pause of about 1 second.
Automatic memory storage
MITTO2
only TRC2/
The key T1 of the transmitter is automatically stored on the output
with impulse output
CH1 while the key T2 on CH2. Do not store the TRC1 with this function
(key T2 is not available).
SW2
SW1
3 blinks followed by a
pause of about 1 second.
Step-by-step output
The combined output relay changes its status each time the
transmitter key is pressed.
SW2
SW1
4 blinks followed by a
pause of about1 second.
Timer output
Each time the transmitter key is pressed, the output relay remains picked
up for 90 seconds. If the key is pressed during the counting cycle, counting
is restarted for further 90 seconds.
SW2
SW1
5 lampeggi seguiti da una
pausa di circa 1 secondo
Code elimination
Remove the from the receiver memory a single T key of a transmitter
SW2
SW1
6 blinks followed by a pause
of about 1 second.
Cancellation of the
entire receiver
memory
WARNING ! This operation deletes all of the radiocontrols stored on channel 1 and
channel 2 from the memory of the receiver.
SW2
SW1
8 -
INTRIC 1-2/TRC 1-2-4/MITTO 2-4 433 Mhz- Ver. 06
INSTALLATION MANUAL
alkaline battery.When replacing the batteries type CR2016 do not touch the
poles with thehands.
Any reduction in the transmitter capacity may be due to the batteries getting
flat. When the led of the transmitter flashes, it means that the batteries are
flat and must be replaced.
7) DISPOSAL
ATTENTION: disposal should only be carried out by qualified personnel.
Materials must be disposed of in conformity with the current regulations.
In case of disposal, the system components do not entail any particular
risks or danger. In case of recovered materials, these should be sorted out
by type (electrical components, copper, aluminium, plastic etc.).
For battery disposal, refer to the current regulations.
The descriptions and illustrations contained in the present manual
are not binding. The Company reserves the right to make any
alterations deemed appropriate for the technical, manufacturing
and commercial improvement of the product, while leaving its
essential features unchanged, at any time and without undertaking
to update the present publication.
When pressing the key SW1 (for channel 1) or SW2 (for channel 2) for the first time, the receiver sets to the programming
mode. Every time the key SW is pressed after that, the receiver switches to the configuration for the subsequent function, that
is indicated by the number of flashings (see table).
For example, if SW2 is pressed for 4 consecutive times, the receiver stores the second channel as timer output
(4 flashings/pause/4 flashings/pause/...).
At this stage, after selecting the channel (SW1 or SW2) and the desired function, the key T (T1-T2-T3 or T4) of the transmitter
will be stored in the memory of the receiver as indicated in the table for programming.
To set the TEO transmitters, it is necessary to press the key T (T1-T2-T3 or T4) for two consequent times.
1
1
1
1
1
1
1
1

Standard Programming

Press
the
transmitter until the Led remains on, then press the
key T (1-2-3 or 4) on the transmitter until flashing is
resumed, wait for the Led to switch off (90secs.) or
disconnect the power supply. Now the key T of the
transmitter is stored.
Press the hidden key P1 (Fig.2) on the transmitter until the Led remains
on, then press the key T1 on the transmitter (pressing of the other keys is
ignored), until flashing is resumed, wait for the Led to switch off (90secs.)
or disconnect the power supply.
Now the keys T1 and T2 are automatically stored on CH1 and CH2.

Advanced Programming

Press the hidden key P1 (Fig.2/Fig.5) on the transmitter until the Led
remains on, then press the key T (1-2-3 or 4) on the transmitter until
flashing is resumed, wait for the Led to switch off (90secs.) or disconnect
the power supply. Now the key T of the transmitter is stored with step-by-
step mode.
Press the hidden key P1 (Fig.2/Fig.5) on the transmitter until the Led
remains on, then press the key T (1-2-3 or 4) on the transmitter until
flashing is resumed, wait for the Led to switch off (90secs.) or
disconnect the power supply. Now the key T of the transmitter is
stored with timer functioning mode.
Press the hidden key P1 (Fig.2) on the transmitter until the Led
1
remains on, then press the key T which has to be cancelled from
the memory of the receiver until flashing is resumed., wait for the
Led to switch off (90secs.) or disconnect the power supply.
While the Led is flashing, simultaneously press the
1
keys SW1 and SW2 on the receiver for more than
10secs.
Now all of the transmitters have been cancelled
and the programming mode is abandoned.
hidden
key
P1
(Fig.2/Fig.5)
on
the

Publicité