AL
NO SWITCH-ON
05
AL
PELLETS FINISHED
06
AL
RESET THERMAL BREAKER /
07
PELLET DOOR OR GATE OPEN
AL
DEPRESSURIZATION
08
AL
FUME EXHAUST SYSTEM
12
FAILURE
AL
SCREW PHASE
14
AL
AUGER TRIAC
15
NO FLOW
AL
(only if the RDS system is
17
provided)
Positions of the switch
protected by a screw cap and
of the reset safety thermostat
located on the
side.
Use and maintenance manual RBC 8010 - 8012
- The pellet tank is empty
- Pellet calibration and suction during
switch on phase is incorrect.
- The igntition coil is faulty or positioned
- The pellet tank is empty.
- The gear motor is not loading pellets
- Not enough pellets loaded
- The manual reset thermostat has tripped
connected to the hopper (RESET
THERMAL BREAKER / Pellet door or gate
is open
- Combustion in the grate is not optimal
due to the fact that the grate is clogged or
the inner stove ducts are clogged. (RESET
THERMAL BREAKER)
- The flue is blocked.
- The vacuum meter is faulty.
- T he fume exhaust system has a loss
of performance due to fan obstruction or
voltage drop.
- No cable connection to power the gear
motor of the auger
- An internal part of the electronic board
that controls the pellet infeed screw is
faulty.
- Possible voltage drops or incorrect input
voltage stove inlet
- The flow meter does not measure inlet
air flow
Rev.1 17/06/2021
- Check for the presence of pellets in the
container. Top up, if necessary.
- Contact the Support Service
- Contact the Support Service
- Check for the presence of pellets in the
container. Top up, if necessary.
- Empty the tank to see if there are any
objects inside that may prevent the
proper operation of the auger.
- Regulate pellets setting from "SET AIR/
PELLETS"
- If the problem persists, contact the
Support Service Support
- Reset the thermostat by pressing the
button on the back of the stove or close
the doors.
- Switch off the stove, clean the brazier
and the tube bundle and adjust the
combustion setting the Pellet/Air values
- Contact the Support Service
Check the flue is free and clean
- Contact the Support Service
- Contact the Support Service
- Contact the Support Service
- Contact the Support Service
- Check the mains voltage.
- Check if the ash pan and door are
closed correctly and check if the air inlet
pipe is
obstructed.
- If the problem persists, contact the
Support Service
Pag.37