Stove phase synthetical layout
PHASE
FINAL CLEANING
SWITCH ON
WAITING FOR FLAME
FLAME PRESENT
AREAS
WORK MODULA
THE GRATE
ECO STOP
START/RESTART WAIT
SWITCH ON RESTART
HOT SMOKE
OFF
WAIT FOR PELLETS
OUT OF
INFEED SCREW
OVERFLOW
Excessive
Load
Use and maintenance manual RBC 8010 - 8012
DESCRIPTION
The stove is in the switch off phase and the cooling phase has not been completed
yet.
The heater pre-heating phase has started and the pellets start to fall into the grate.
The pellets ignite and take advantage of the heat in the intake air that passes
through the
incandescent heater tube.
The flame is visible in the grate.
The stove has completed the switch on phase and runs at maximum set capacity.
The room temperature set has been reached.
Brazier cleaning phase is active (periodic function).
With Climate Comfort active, the stove switches to automatic switch-off mode
when
the room temperature set is reached (see the dedicated section).
Switch-on is requested but with the stove in cooling phase; once this condition is
met, it
restarts automatically.
The HOT restart phase is activated.
Functioning is similar to the SWITCH ON phase
The maximum fume temperature threshold has been reached. To facilitate cooling,
the
stove brings the capacity to a minimum with ventilation at power level 5, leading to
a decrease
The stove is off
When the switch-on request from ECO-STOP mode coincides with an
automatic switch-off condition (from the TIMER), the stove turns on ensuring total
cleaning
of the brazier before switching to FINAL CLEANING.
CONDITION: when the pellet setting (set pellets +5) is near the continuous load
condition.
SOLUTION: Set the value back to 0.
Rev.1 17/06/2021
Pag.35