General Terms And Conditions Of Service And Warranty - Inventum IVW6040AXL Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Problem
FAULT CODES
The fault codes are shown on the display of the control panel.
Fault code
Possible cause
F5
There is insufficient water supply.
F3
The water supply does not stop.
F2
The waste water in the appliance cannot
be discharged.
F8
The heater has an error.
F1
The safety for water overflow is
activated.
FE
There is an electronic error.
F7
The temperature of the appliance is too
high.
F9
The position of the distributor has an
error.
F6
The heat sensor has an error.
9

General terms and conditions of service and warranty

We do not need to remind you of the importance of service. After all, we develop our products to a standard so that
you can enjoy them for many years, without any concerns. If, nevertheless, there is a problem, we believe you are
entitled to a solution straight away. Hence our products come with an exchange service, on top of the rights and
claims you are entitled to by law. By exchanging a product or part, we save you time, effort and costs.
2-year full manufacturer's warranty
1. Customers enjoy a 2-year full manufacturer's warranty on all Inventum products. Within this period, a faulty
product or part will always be exchanged for a new model, free of charge. In order to claim under the 2-year full
manufacturer's warranty, you can either return the product to the shop you bought it from or contact the Inventum
costumer service department via the form at
2. The 2-year warranty period starts from the date the product is bought.
Possible cause
Any spilled salt during filling of the
salt reservoir was not cleaned
immediately.
The water supply is polluted.
Possible solution
Make sure that the water tap is fully open and that
the water supply is not blocked.
Close the water tap, remove the water inlet hose and
do a check if the hose is clogged.
Start the appliance again.
Contact the Inventum-servicedienst if the fault code
keeps re-occuring.
Close the water tap.
Contact the Inventum-servicedienst.
Do a check if the drain hose is clogged.
Do a check if the filters are clogged.
Switch the appliance off and reset the program. Refer
to section
Contact the Inventum-servicedienst if the fault code
keeps re-occuring.
Contact the Inventum-servicedienst.
Contact the Inventum-servicedienst.
Contact the Inventum-servicedienst.
Contact the Inventum-servicedienst.
Contact the Inventum-servicedienst.
Contact the Inventum-servicedienst.
'https://www.inventum.eu/service-aanvraag'
Possible solution
Make sure that you clean any spilled
salt immediately and run a full
program to prevent corrosion.
Do a check on the water supply.
'Resetting the program'
.
.
English
51

Publicité

Table des Matières
loading

Table des Matières