7.4
Connecting power tools
WARNING
Risk of injury
► Observe the maximum electrical outlet
module connected load (see section "Tech­
nical data").
► Switch off the power tool.
Connecting a mains-powered power tool to the
mobile dust extractor
► Connect the power tool to the electrical out­
let module [1-1].
The power tool is connected to the mobile dust
extractor via the power cable.
8

Settings

8.1
Adjusting the suction power
► Press the plus or minus button [1-12] while
extracting.
8.2
Temperature cut-out
A temperature cut-out switches the mobile dust
extractor off when it reaches a critical tempera­
ture to prevent overheating. The bottom
LED [1-12] indicates a fault.
LED lights up red
► Switch off the mobile dust extractor, let it
cool down.
► Switch on the mobile dust extractor again
after approx. five minutes.
9

Working

9.1
Dust extraction
Extracting dry materials
Always use a filter bag.
9.2
Extracting wet materials/liquids
Remove the filter bag!
Use a special wet filter.
The dust extractor stops automatically when
the maximum fill level is reached.
The bottom LED [1-12] lights up red.
► Switch off the mobile dust extractor [1-10].
► Open the locking clips [1-7] and remove the
top section of the machine.
► Empty the dirt trap [1-9].
After wet extraction, allow the main filter to dry!
Dry the mobile dust extractor before extracting
dry dust.
12
Excessive temperature
CAUTION
Hazardous dust
Damage to the respiratory passage
► After extracting wet materials, remove the
wet filter and replace it with the main filter
for dry materials.
CAUTION
Escaping foam and fluids
► Switch off and empty the machine immedi­
ately.
9.3
Blow-out function
► Open the grille in front of the exhaust open­
ing [1-8].
► Insert the suction hose in the exhaust open­
ing [1-8].
► In standby mode, press the MAN but­
ton [1-11].
9.4
Changing the filter bag with minimal
dust
► Open the locking clips and remove the top
section of the machine [2].
► Pull the tab on the filter bag until the filter
bag opening is fully closed.
The filter bag is now securely closed and can be
removed.
► Fit the top section of the machine and close
the locking clips.
9.5
Changing the filter element [6]
► Pull out the used filter drawer [1-6].
► Dispose of the used filter drawer in accord­
ance with statutory regulations.
► Insert the new filter drawer [1-6].
Order numbers for accessories, filters and
consumables in the Festool catalogue or
online at "www.festool.com".
Only use original Festool accessories and
consumables. Only accessories tested and
approved by Festool are safe and perfectly
adapted to the machine and application.
NOTICE
Damage to the motor
► Never extract material without a main filter
or with a damaged main filter, as this can
damage the motor.