Advanced Management - Bentel Security BTEL-3G Manuel D'installation

Avertisseur téléphonique 3g/2g
Masquer les pouces Voir aussi pour BTEL-3G:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Advanced Management

This section mainly describes the procedures for programming the way the inputs and outputs work, as well as the
dialler's advanced features.
Management Input Polarity
To program activation of the 4 inputs (for more information, see the section on "Connecting the device->Activation
Polarity"), type the following keypad sequence:
where <Input no.> is the number of the input being programmed (from
(factory default setting) or negative
Periodic Message
In this menu one can program the periodic sending of voice message no. 8 to the number stored in the phone book as
no. 1. For further information, consult the sections "Parameters Management->Phone Book Management" and
"Parameters Management->Voice Message Management". To program this option, type the following keypad
sequence:
where <No. of days> corresponds to the number of days until a message is sent (from
transmission, press
. The factory default setting is 0 (disabled).
Language change
In this menu you can change the language for the voice commands. To program this feature, type the following keyboard
sequence:
where <Language> corresponds to :
Set Date and Time
To program this feature, type the following keyboard sequence:
for each parameter, such as <Hour><Minutes><Day><Month><Year>, type two digits, for example, to set the date to the
third day of the month, press
     After scheduling a new date, any regularly sent text messages in the system must be re-entered.
Output Management
The 4 Open Collector Outputs can be activated automatically (when pre-programmed events take place). This menu
is used to program the Outputs, their polarity (N.C. or N.O.), their status as 'Monostable' or 'Bistable', activation via caller
recognition, and confirmation of the outputs activation.
     Output Type Management
Open Collector Outputs OC1, OC2, and OC3 can be set as Bistable (activation and deactivation take place through two
different commands) or as Monostable (the output remains active for its ON Time, after which it returns to standby status;
Output OC4 is preset as Bistable only. To program this feature, type the following keypad sequence:
   
<Output no.>
   
<Output no.><ON Time> (to set to Monostable - factory default setting)
where <Output no.> is the number of the output being programmed (from

from
to
(factory setting: 10 seconds).
     Monostable OC Outputs return to standby after the set ON Time.
3G/2G Telephone dialler
  
<Input no.><Polarity>
    
. For example
  
<No. of days>
  
=Italian
=English
  
<Hour><Minutes><Day><Month><Year>

and for the year 2012 press
(to set to Bistable)
to
), while <Mode> can be positive
programs input no. 2 for negative polarity.
<Language>
=French
=Spanish.

.
to
) while the <ON Time> is in seconds,

to
); to disable
15
EN

Publicité

Table des Matières
loading

Table des Matières