Cameo ZENIT Z120 G2 Manuel D'utilisation page 10

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
Settings (bold = factory setting)
Display Reverse
=
Display Backlight
=
DMX Fail
=
Dimmer Curve
=
Dimmer
=
Response
PWM Frequency
=
Autolock
=
Calibration
=
Zoom Reset
=
Factory Reset
=
DIMMER CURVES
linear
DMX value
10
Display rotation
Display lighting
operating status with DMX signal
fault
dimmer curve
Dimmer response
LED PWM frequency
Automatic locking of the controls
Colour and zoom calibration
Initialise zoom unit
reset to factory settings
exponential
logarithmic
DMX value
DMX value
On
Display is rotated through 180° (e.g. for overhead
installation)
Off
No display rotation
On
on permanently
Off
Deactivates after approximately 30 seconds of
inactivity
Hold
Last command is retained
Blackout
Activates blackout
Linear
Light intensity increases linearly with DMX value
Exponential
Light intensity can be finely adjusted at lower
DMX values and broadly adjusted at higher DMX
values
Logarithmic
Light intensity can be broadly adjusted at lower
DMX values and finely adjusted at higher DMX
values
S-Curve
Light intensity can be finely adjusted at lower
and higher DMX values and broadly adjusted at
medium DMX values
LED
Lamp responds abruptly to changes in DMX value
Halogen
= spotlight behaves like a halogen spotlight with
soft brightness changes
800 Hz/1200
Configuration of LED PWM frequency
Hz/2000 Hz/ 3600
Hz/12 kHz/25 kHz
On
Automatic locking of the controls after approxi-
mately 30 seconds of inactivity. Display shown
upon attempted use: "LOCKED"
To unlock: Press and hold UP and DOWN simulta-
neously for approx. 5 seconds
Off
Automatic locking of the controls is disabled
Red, Green, Blue,
Individual colour calibration. Cross-mode configu-
White, Zoom
ration of the 4 LED groups RGBW and of the zoom
function with values of 000–255
Reset?
Initialise zoom unit:
confirm with ENTER, cancel with MODE
Reset?
Reset to factory settings:
Confirm with ENTER. Cancel with MODE
S-curve
DMX value

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Clzz120g2

Table des Matières