WANDERS Larix Mode D'emploi Et Instructions D'installation page 30

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
Placing the fi replace (standing)
The device must be mounted on a suffi ciently sturdy fl oor.
Remove the top and bottom front covers and the glass, as described on page 29.
Place the heater on its base and secure it with 4 M8 bolts. These are located to the left and right of a gas unit.
Level the heater with the adjustable legs.
Make sure to keep fl ammable materials, such as curtains, well clear of the system at a minimum distance of 1.5m.
Installing the reducer
Depending on the length and shape of the concentric channel
system Ø 100 - Ø 150 mm and the outlet construction, a restrictor
with a diameter of Ø 35 mm, Ø 50 mm, Ø 60 mm or Ø 80 mm
according to the tables on page 28 must be installed in the top
of the combustion chamber. The standard culvert for the fl ue
gases is Ø 100 mm.
Ensure that the reducer is properly fi tted. Fitting the
reducer incorrectly may cause defects to the
appliance.
30

Publicité

Table des Matières
loading

Table des Matières