Summary Of The Conditions Of Transmission Of Uplink Frames - ADEUNIS WMBUS DRY CONTACTS Guide Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WMBUS DRY CONTACTS - Guide utilisateur / User guide version V2.0.0

4.2.6 Summary of the conditions of transmission of uplink frames

The table below summarizes the conditions of the transmission of the different uplink frames:
Code
0x10
Product configuration data frames
FR
0x20
Frame of information on the network
configuration
0x30
Keep Alive frame
EN
0x40
Data Frame
Description
• Start-up of the product
• Exit from the configuration mode (AT Command)
• Reception of a downlink frame 0x01
• Periodically if the inputs are disabled (period defined by the register 300)
• Start-up of the product
• Exit from the configuration mode (AT Command)
• Reception of a downlink frame 0x02
• Periodically if all the TORs are configured in event mode or as outputs
• Start-up of the product
• Event on an input configured in event mode
• The end of the period on input configured in periodic mode
Scenarii d'envoi
64 of 75