Installing the water line.
Read these instructions completely and carefully.
Before You Begin
If the water supply to the refrigerator is from a Reverse Osmosis Water Filtration System
and the refrigerator is equipped with a built-in filtration system, it is not necessary to use
the refrigerator's water filter. Use the refrigerator's Filter Bypass Plug. Using the
refrigerator's water filtration cartridge in conjunction with the RO filter can result in hollow
ice cubes and slower water flow from the water dispenser.
This water line installation is not warranted by the refrigerator or icemaker manufacturer.
Follow these instructions carefully to minimize the risk of expensive water damage.
Water hammer (water banging in the pipes) in house plumbing can cause damage to
refrigerator parts and lead to water leakage or flooding. Call a qualified plumber to correct
water hammer before installing the water supply line to the refrigerator.
To prevent burns and product damage, do not hook up the water line to the hot water line.
If you use your refrigerator before connecting the water line, make sure the icemaker feeler
arm is kept in the STOP (up) position.
Do not install the icemaker tubing in areas where temperatures fall below freezing.
When using any electrical device (such as a power drill) during installation, be sure the
device is insulated or wired in a manner to prevent the hazard of electric shock.
All installations must be in accordance with local plumbing code requirements.
What You Will Need
To determine how much copper tubing you need:
Measure the distance from the water valve on the back of the refrigerator to the water
supply pipe. Then add 8 feet (244 cm). Be sure there is sufficient extra tubing [about 8 feet
(244 cm) coiled into 3 turns of about 10 inches (25 cm) diameter] to allow the refrigerator to
move out from the wall after installation.
A water supply kit
available at extra cost from your dealer or from Parts and Accessories, 800-626-2002.
Cold water supply. The water pressure must be between 40 and 120 p.s.i.
Power drill.
Copper tubing,
both ends of the tubing are cut square.
Do not use plastic tubing or plastic fittings because the water supply line is under
pressure at all times. Certain types of plastic tubing may become brittle with age and
crack, resulting in water leakage.
1/4² outer diameter compression nuts and 2 ferrules (sleeves)— to connect the copper
Two
tubing to the shutoff valve and the refrigerator water valve.
If your existing water line has a flared fitting at the end, you will need an adapter (available at
plumbing supply stores) to connect the water line to the refrigerator OR you can cut off the
flared fitting with a tube cutter and then use a compression fitting.
Shutoff valve to connect to the cold water line. The shutoff valve should have a water inlet
with a minimum inside diameter of 5/32² at the point of connection to the COLD WATER
LINE. Saddle-type shutoff valves are included in many water supply kits. Before purchasing,
make sure a saddle-type valve complies with your local plumbing codes.