Télécharger Imprimer la page

Bionest SA-3 Guide D'utilisation page 38

Masquer les pouces Voir aussi pour SA-3:

Publicité

Les langues disponibles

Les langues disponibles

It is the owner's responsibility to respect all applicable regulation in effect, namely regarding the
system's maintenance and discharge standards as well as any discharge into the environment.
The septic tank and BIONEST® reactor must always be completely filled with clear
water prior to starting the recirculation and air pumps.
In case of a new construction, make sure the building is being used before starting
the recirculation and air pumps and using the system.
Using your system when the air pump is not operating may cause serious
consequences (exterior odors, clogging of polishing field, warranty cancellation).
In order to ensure proper and efficient functioning of your BIONEST® wastewater
treatment system and polishing field (if applicable), it is crucial that the following
instructions be respected.
3
These instructions also apply to any septic installation type. For further details, you may refer
to the MDDELCC's «Guide de bonnes pratiques» (French) http://www.mddelcc.gouv.qc.ca/eau/
eaux-usees/guide-bonnes-pratiques-proprio-dispositifs.pdf.
NEVER dispose of the following in any of the building's sanitary facilities :
• Paints (latex, acrylic or alkyd), plaster and solvents (do not rinse
paint brushes in any sanitary facility)
• Caustic clog removers (Liquid-Plumr®, Drano®, etc.)
• Petroleum products, waxes and resins, oils and greases (domestic and/or
industrial)
• Wastewaters from a recreational vehicle
• Large quantities of household cleaning products or chlorine bleach
• Large quantities of antibacterial products (hand or dishwashing soaps)
• Automatic toilet or shower cleaners
• Pesticides
• Septic tank additives
• Any non biodegradable object (cigarette butts, sanitary napkins, tampons, condoms, etc.)
Use of a waste disposal unit is not recommended, as it increases suspended
solids and soluble organic load, causing premature clogging of the effluent
filter and BIONEST® reactor.
Owner's manual SA
i
mpOrtant Operating instructiOns
12
3
2014-10-01
DOC0014

Publicité

loading

Ce manuel est également adapté pour:

Sa-10000