Télécharger Imprimer la page

Bionest SA-3 Guide D'utilisation page 32

Masquer les pouces Voir aussi pour SA-3:

Publicité

Les langues disponibles

Les langues disponibles

System performances
Under normal operating conditions, the BIONEST® treatment system renders performances meeting
Class III advanced secondary and Class V tertiary with disinfection (when combined with a UV
lamp) treatment requirements.
1
Table 1 : BIONEST® system purifying performance
Parameter
Standard
Average
results***
BOD
C: Biochemical oxygen demand 5 days, carbonaceous
5
TSS: Total suspended solids
CFU : Colony forming units
* After reactivation
** Before reactivation
*** Obtained upon 12 month NQ 3680-910 certification testing
Model designation and capacity
As required by the Regulation respecting wastewater disposal systems for isolated dwellings
(Q-2, r. 22), the BIONEST® system is certified according to NQ 3680-910 standard for six (6)
bedroom or less dwellings. Bionest offers six (6) certified models for isolated dwellings, according
to the number of bedrooms, as well as for buildings generating a daily flow between 2,161 L/d
and 3,240 L/d.
Table 2 : NQ 3680-910 certified BIONEST® systems for residential applications
No of
bedrooms
1
2
3
4
5
6
-
SA-6C27
-
SA-6C32
Owner's manual SA
BIONEST® system
Advanced secondary
Class III
BOD
C
TSS
5
(mg/L)
(mg/L)
15
15
4
3
Hydraulic
Model
capacity
(L/day)
SA-3
540
SA-3
1,080
SA-3
1,260
SA-4
1,440
SA-5
1,800
SA-6
2,160
2,700
3,240
BIONEST® system with UV unit
Tertiairy with disinfection
Fecal coliforms
(CFU/100 ml)
50,000
4,000
Septic tank
minimal total volume
3.4 m
3
3
3.4 m
3
3.4 m
3
3.9 m
4.3 m
3
4.8 m
3
3
5.7 m
3
6.8 m
6
Class V
Fecal coliforms
(CFU/100 ml)
200*
2**
BIONEST® reactor
minimal total volume
3.4 m
3
3
3.4 m
3
3.4 m
3
3.9 m
4.3 m
3
4.8 m
3
3
5.7 m
3
6.8 m
2014-10-01