62
SC Invoke – Selection & Operation of the Modes
Switching between operating modes
With the device switched on, press the Fire button quickly 3 times to pull up the menu; with one more click, you will
open the MODE options� Press the Setting buttons to switch between the VW, TC-Ni, TC-Ti, TC-SS316, TCR (M1, M2, M3)
and USB functions (if USB is activated)� Press the Fire button to confirm each selection�
Settings in VW Mode
In VW mode, the power – depending on the atomizer head used – can be between 1 and 220 watts� Use the Up
and Down button to increase or decrease the power�
Settings in TC Mode
In the TC (Ni, Ti, SS) and TCR (M1, M2, M3) modes, the temperature can be set simply by pressing the Up or Down but-
ton after selecting the coil or memory position, while the wattage can only be adjusted in the SET subitem POWER�
Note:
1� The TC-SS mode is specially designed for the 316 stainless steel coil�
2� The TC / TCR mode supports a maximum of 1�5 ohms� The device automatically switches to VW mode when the
resistance is greater than 1�5 ohms�
3� When Kanthal wire is used in TC / TCR mode, the device automatically switches to VW mode�