Putting on the housing
11
Fig. 4.4 Putting on the housing
>
Lower the housing onto the two brackets (11) and
push it against the rear wall. Make sure the two lugs
are in the recesses.
>
Tighten the screw (10) below the temperature selec-
tor spindle.
>
Put the power switch (9) and the temperature selec-
tor (1) on again.
4.5.2 Fitting the appliance
>
Decide where to fit the appliance, see 4.2.
>
To mount the appliance, use the recesses and holes
in its rear wall as required.
>
Drill holes for the fastening screws according to the
dimensions shown on the drawing in section 4.3.
>
Depending on the location, use anchor bolts, hooks,
screws or threaded pins.
>
Firmly mount the rear wall of the appliance to the
wall using suitable fixings.
Installation manual atmoMAG mini 11-0/0 XI 838291_05
5

Installation

a
Danger!
Risk of poisoning and explosion!
Incorrect installation may lead to hazardous
situations.
>
When installing the connections, ensure
that all seals are inserted correctly to pre-
vent any risk of gas leaks.
a
Danger!
Risk of scalding!
Incorrect installation may lead to hazardous
situations.
>
When installing the connections, ensure
that all seals are inserted correctly to pre-
vent any risk of water leaks.
5.1

Connecting to the gas supply

1
>
Connect the wall outlet and the appliance inlet with a
gas shut-off valve, making sure the connection is gas-
10
tight and not under strain.
9
b
Caution!
Risk of damaging the gas valve!
The gas valve may be damaged by high pres-
sures. The operating pressure must not
exceed 0.006 MPa (60 mbar).
>
Check the tightness of the gas valve using
a maximum pressure of 0.011 MPa (110
mbar).
>
Check the appliance for leaks and seal them.
5.2

Connecting to the water supply

a
Danger!
Risk of scalding and damage from escaping
hot or cold water!
Incorrect installation may cause leaks. Plastic
pipes for the hot and/or cold water connec-
tion must be resistant to temperatures up to
95 °C and resistant to pressures up to 1 MPa
(10 bar).
>
In order to prevent leaks, ensure that no
mechanical stresses arise in the pipework.
Make sure there are no stresses in the hot
and cold water connections when installing
them.
>
Make the hot and cold water connections, making
sure they are not under strain.
>
Check the appliance for leaks and seal them.
Fitting 4