Problem
No function
No LED lights up.
The yellow LED flashes.
Loud sparking.
The appliance will not start
and the red LED flashes.
The red LED flashes during
operation.
The appliance stops and the
red LED lights up.
Table 5.2 Troubleshooting
If the appliance was blocked by its safety systems, it can
only automatically ignite again once you have "reset" it.
To "reset" the appliance, either:
>
Close the water tap and open it again without press-
ing the main switch, or
>
Leave the water tap open and switch the appliance
off and on again by pressing the main switch (5)
twice.
Depending on the installation conditions, the unit may
have to be "reset" several times before it ignites auto-
matically; this is particularly true when commissioning
the unit and if it has been out of operation for some
time. Please follow the instructions in Section 5.3 Start-
up.
When the fault is eliminated, the gas instantaneous
water heater starts up automatically.
If the malfunction recurs, have an engineer come to
inspect the appliance.
Operating manual atmoMAG mini 11-0/0 XI 838291_05
Cause
Flat batteries.
Low batteries.
Gas supply interrupted.
Air in the gas supply pipe.
Low water pressure.
Gas supply interrupted.
Air in the gas supply pipe.
Low batteries.
Defective safety device.
Remedy
Replace the batteries with new ones.
Ensure the gas supply.
Make sure the cold water shut-off valve is open.
If the problem persists, notify your heating engineer.
Replace the batteries with new ones.
Ensure the gas supply.
For liquid gas:
Replace an empty gas bottle with a full one.
Make sure that the cut-off valve on the gas connection is open.
Open and close the water tap several times to get rid of air in the
gas supply.
If the problem persists, notify your heating engineer.
Ensure the gas supply.
For liquid gas:
Replace an empty gas bottle with a full one.
Open and close the water tap several times to get rid of air in the
gas supply.
If the problem persists, notify your heating engineer.
Make sure the cold water shut-off valve is open.
Replace flat batteries with new ones.
Contact your heating engineer.
a
Danger!
Inappropriate alterations may cause dam-
age!
Inappropriate alterations may lead to hazard-
ous situations.
>
Under no circumstances should you ever
attempt to make alterations to the gas
fired instantaneous water heater or other
parts of the system by yourself.
>
Never try to carry out maintenance work
or repairs on the unit yourself.
>
Always employ a qualified specialist
tradesman.
Only use the gas instantaneous water heater again once
the malfunction has been rectified by an engineer.
a
Danger!
Risk of carbon monoxide poisoning!
If air flow conditions in the chimney are per-
manently poor, flue gases may flow back
unchecked from the chimney into the installa-
tion room if the atmospheric sensing device is
not operating.
>
Under no circumstances should you switch
off the atmospheric sensing device (flue
gas sensor).
>
Never tamper with this device as this may
prevent it from operating correctly.