Troubleshooting
Problem
Cause
Wrench does
No battery
not turn on
installed/ battery is
when power
not charged
button is
Firmware Issue
pressed.
Torque
Calibration
reading
required
is out of
specification.
Wrench
Battery was
settings were
removed before
not saved
the setting was
once battery
saved.
was removed.
Torque zero
Torque applied
error
while zeroing.
Wrench is over
torqued.
Wrench was not
calibrated correctly.
Failure to the
torque sensor.
Overtorque
125% of the max
torque rating has
been applied to
the tool.
Torque
150% of max
overload
torque rating has
been applied to
the tool.
Display
Memory failure
memory error.
Display
Torque is
torque
uncalibrated.
uncalibrated.
Display
Tool needs
warning
attention.
Display
Battery has
battery over
exceeded peak
temperature
temperature while
running.
Display
Tool has exceeded
tool over
peak temperature
temperature
while running.
Display
Tool will exceed
certification
the expiration date
needed soon.
for certification
soon.
Display out of
Tool exceeded the
certification.
expiration date
that is required for
certification, tool
is overloaded, or
5000 tightening
cycles have
surpassed.
Solution
Insert / Replace
battery
Turn tool OFF and
remove battery
Return to a service
center to be
calibrated.
Return to a service
center to be
calibrated.
Re-enter settings,
press and hold
Power button to
power down the tool
before removing the
battery.
Remove the torque
and re-zero the tool.
Return to a service
center to be
calibrated.
Return to a service
center to be
calibrated.
Return to a service
center.
Return to a service
center to be
calibrated.
Return to a service
center to be
calibrated.
Clear the data in
memory.
Return to a service
center to be
calibrated.
Follow steps
through warning to
proceed.
Turn the tool off and
remove the battery.
Allow the battery to
cooldown.
Turn the tool off and
remove the battery.
Allow the tool to
cooldown.
Return to a service
center to be
calibrated.
Return to a service
center to be
calibrated.
6
MAINTENANCE
To reduce the risk of injury, always
WARNING
unplug the charger and remove the
battery pack from the charger or tool before
performing any maintenance. Never disassemble
the tool, battery pack or charger. Contact a
MILWAUKEE service facility for ALL repairs.
Maintaining Tool
Keep your tool, battery pack and charger in good
repair by adopting a regular maintenance program.
Inspect your tool for issues such as undue noise,
misalignment or binding of moving parts, breakage of
parts, or any other condition that may affect the tool
operation. Return the tool, battery pack, and charger
to a MILWAUKEE service facility for repair. After six
months to one year, depending on use, return the
tool, battery pack and charger to a MILWAUKEE
service facility for inspection.
If the tool does not start or operate at full power with
a fully charged battery pack, clean the contacts on
the battery pack. If the tool still does not work prop-
erly, return the tool, charger and battery pack, to a
MILWAUKEE service facility for repairs.
To reduce the risk of personal in-
WARNING
jury and damage, never immerse
your tool, battery pack or charger in liquid or
allow a liquid to flow inside them.
ONE-KEY™
Chemical Burn Hazard.
WARNING
This device contains a
lithium button/coin cell battery. A new
or used battery can cause severe in-
ternal burns and lead to death in as
little as 2 hours if swallowed or enters the body.
Always secure the battery cover. If it does not
close securely, stop using the device, remove the
batteries, and keep it away from children. If you
think batteries may have been swallowed or en-
tered the body, seek immediate medical attention.
Internal Battery
An internal battery is used to facilitate full ONE-KEY™
functionality.
To replace the battery:
1. Remove the battery pack.
2. Remove the screw and open the battery door.
3. Remove the old battery, keep it away from children,
and dispose of it properly. NOTE: Retain and re-
install the battery removal tab on the replacement
battery prior to installing.
4. Insert the new battery (3V CR2032), with the posi-
tive side facing up.
5. Close the battery door and tighten the screw
securely.
Cleaning
Clean dust and debris from vents. Keep trigger
handle clean, dry and free of oil or grease. Use
only mild soap and a damp cloth to clean, since
certain cleaning agents and solvents are harmful to
plastics and other insulated parts. Some of these
include gasoline, turpentine, lacquer thinner, paint
thinner, chlorinated cleaning solvents, ammonia and
household detergents containing ammonia. Never
use flammable or combustible solvents around tools.
For repairs, return the tool, battery pack and charger
to the nearest service center.
Repairs